{
  "caseId": "CASE-HYBRID-OVERLAP",
  "version": "1.0.0",
  "model": "synthetic-disjoint-record-residualization-v1",
  "createdAt": "2026-11-05",
  "status": "author-invented-inventory-only-teaching-model",
  "numericProvenanceDefault": "AUTHOR-INVENTED: every annual flow, price, emission and technology coefficient in this generator network",
  "linkedService": {
    "caseId": "CASE-WALL-CONNECT",
    "version": "1.0.0",
    "inputFile": "wall-coating-v1.json",
    "inputSha256": "cc2ba86f5aedfe49437088034382418a5c58a5020c04ba07c6289b9962eae285",
    "scenario": "smooth",
    "alternative": "paintA",
    "area": "100",
    "areaUnit": "m2",
    "intervalYears": "[0,10)",
    "treatmentTimesYears": [
      "0",
      "5"
    ],
    "kgPerM2PerTreatment": "0.05",
    "paintKg": "10",
    "electricityKWhPerKgPaint": "2",
    "fixedElectricityDeliveryKWh": "20",
    "scope": "electricity-subinventory-only",
    "oldAggregatedElectricityBurdensAdded": false,
    "paintNonElectricBurdensAdded": false,
    "wallClimateScoreCalculated": false,
    "alternativesCompared": false
  },
  "annualBasis": {
    "periodYears": "1",
    "region": "fictional-region",
    "priceYear": "fictional-year",
    "currencyUnit": "CU",
    "priceBasis": "producer",
    "electricityPriceCUPerKWh": "1",
    "transactionUnit": "CU/year",
    "emissionUnit": "kg CO2/year",
    "stationaryOverLinkedService": true,
    "repeatedSteadyTechnology": true,
    "marginsIncluded": false,
    "taxesIncluded": false,
    "importsIncluded": false,
    "capitalIncluded": false,
    "lossesIncluded": false,
    "coProductsIncluded": false
  },
  "suppliers": {
    "F": {
      "output": "100",
      "outputUnit": "kWh/year",
      "outputValueCU": "100",
      "directCO2Kg": "40",
      "commodity": "E",
      "industry": "E"
    },
    "G": {
      "output": "100",
      "outputUnit": "kWh/year",
      "outputValueCU": "100",
      "directCO2Kg": "120",
      "commodity": "E",
      "industry": "E"
    },
    "S": {
      "output": "100",
      "outputUnit": "CU/year",
      "outputValueCU": "100",
      "directCO2Kg": "30",
      "commodity": "S",
      "industry": "S"
    }
  },
  "transactions": {
    "rowSupplierOrder": [
      "F",
      "G",
      "S"
    ],
    "columnConsumerOrder": [
      "F",
      "G",
      "S"
    ],
    "identified": {
      "description": "F and G each supply 10 CU of power to S",
      "annualCU": [
        [
          "0",
          "0",
          "10"
        ],
        [
          "0",
          "0",
          "10"
        ],
        [
          "20",
          "30",
          "20"
        ]
      ]
    },
    "sameAggregateCounterworld": {
      "description": "G supplies all 20 CU of power to S; F supplies none",
      "annualCU": [
        [
          "0",
          "0",
          "0"
        ],
        [
          "0",
          "0",
          "20"
        ],
        [
          "20",
          "30",
          "20"
        ]
      ]
    }
  },
  "residualization": {
    "foregroundSupplier": "F",
    "removeForegroundMakeAndDirectEmissions": true,
    "removeIdentifiedForegroundPurchases": true,
    "removeIdentifiedForegroundSales": true,
    "removalRule": "each identified annual transaction incident to F is removed once from raw use; its original direction determines the bridge",
    "normalization": "remaining use columns divided by remaining commodity output values; remaining emissions divided by those same outputs",
    "commodityOrder": [
      "E",
      "S"
    ],
    "foregroundActivityUnit": "kWh",
    "residualActivityUnits": [
      "CU",
      "CU"
    ],
    "directInventoryUnit": "kg CO2",
    "upstreamUnit": "CU/kWh",
    "downstreamUnit": "kWh/CU"
  },
  "controls": {
    "finalDemand": [
      "20",
      "0",
      "0"
    ],
    "finalDemandCoordinates": [
      "F kWh",
      "E CU",
      "S CU"
    ],
    "processOnly": "F direct emissions for fixed 20 kWh; both bridges omitted",
    "naive": "same identified explicit bridges plus unadjusted raw IO coefficients and raw IO emissions",
    "corrected": "both bridges plus remaining accounts after exact record removal and renormalization",
    "counterworld": "same raw aggregates, prices, outputs, emissions and final demand; only the supplier identity of power sold to S changes",
    "misidentification": "apply the identified-world 10 CU F-to-S invoice removal and bridge to the counterworld, where that invoice is actually G-to-S"
  },
  "interpretation": {
    "authorDesignedSpecialCase": true,
    "informedBySuhConceptually": true,
    "sourceCoefficientsReused": false,
    "literalGeneralAppendixA7Implementation": false,
    "sourceResidualizationReconstructed": false,
    "empiricalCalibration": false,
    "scientificValidation": false,
    "realSupplierData": false,
    "characterizationFactors": null,
    "climateImpactScore": false,
    "wholeWallLifeCycle": false,
    "equalAggregatesIdentifySupplierOverlap": false,
    "uncertaintyPropagated": false
  }
}
