  "caseId": "CASE-WALL-CONNECT",
  "version": "1.0.0",
  "createdAt": "2026-11-04",
  "status": "hypothetical-teaching-model; arithmetic and semantic scope reviewed; not an empirical comparative LCA",
  "numericProvenanceDefault": "AUTHOR-INVENTED: every performance, inventory, energy, scenario, range and tolerance number; only the explicitly sourced characterization factors are exceptions",
  "service": {
    "area": "100",
    "areaUnit": "m2",
    "intervalYears": "[0,10)",
    "performance": "Continuous uniform specified colour and stipulated opacity at least 0.98; indoor dry wall; no other functional requirement claimed",
    "paintA": {
      "kgPerM2PerTreatment": "0.05",
      "treatmentTimesYears": [
        "0",
        "5"
      ],
      "stipulatedLifeYearsPerTreatment": "5",
      "requiredKg": "10"
    },
    "paintB": {
      "kgPerM2PerTreatment": "0.06",
      "treatmentTimesYears": [
        "0"
      ],
      "stipulatedLifeYearsPerTreatment": "10",
      "requiredKg": "6"
    },
    "assumptions": [
      "No application loss",
      "Instantaneous renewal with no downtime",
      "Stationary processes and performance over ten years",
      "No removal needed for A renewal",
      "Application equipment and labour omitted",
      "No disposal or recovery model",
      "Paint identities fictional, substance identities CO2 and fossil CH4 real but quantities invented"
    ]
  },
  "technosphere": {
    "columns": [
      "P-A: one operation supplies 1 kg ready-to-apply Paint A",
      "P-B: one operation supplies 1 kg ready-to-apply Paint B",
      "P-P: one operation prepares 1 m2 substrate",
      "P-E: one operation supplies 1 kWh electricity"
    ],
    "rows": [
      "Paint A, kg",
      "Paint B, kg",
      "preparation service, m2",
      "electricity, kWh"
    ],
    "signConvention": "output positive, intermediate input negative; columns are per stated process operation; s contains dimensionless counts of those operations; f row entries retain each row's unit",
    "matrix": [
      [
        "1",
        "0",
        "0",
        "0"
      ],
      [
        "0",
        "1",
        "0",
        "0"
      ],
      [
        "0",
        "0",
        "1",
        "0"
      ],
      [
        "-2",
        "-5",
        "-0.2",
        "1"
      ]
    ],
    "equations": [
      "A s = f",
      "sA=fA",
      "sB=fB",
      "sP=fP",
      "sE=2*sA+5*sB+0.2*sP+fE"
    ],
    "determinant": "1",
    "doubleCountingRule": "Non-electric burdens of paints and preparation exclude P-E burdens. P-E represents its own stipulated aggregated electricity supply burden. No methane oxidation CO2 is separately added."
  },
  "environment": {
    "rows": [
      "CO2, fossil-origin emission to air, kg",
      "CH4, fossil-origin emission to air, kg"
    ],
    "matrix": [
      [
        "2",
        "3",
        "0.05",
        "theta"
      ],
      [
        "0.005",
        "0.01",
        "0",
        "0.001"
      ]
    ],
    "rule": "positive emission; g=B(theta)*s; all entries invented including explicitly assumed zero; no other elementary flows are claimed covered"
  },
  "characterization": {
    "name": "GWP100 using selected central factors from IPCC AR6 WGI Table 7.15 as replaced by errata version 7 October 2025",
    "factorVector": [
      "1",
      "28.1"
    ],
    "factorUnits": [
      "kg CO2-eq/kg CO2",
      "kg CO2-eq/kg fossil CH4"
    ],
    "factorEvidenceIds": [
      "ev-ipcc-ar6-2025-co2-gwp100",
      "ev-ipcc-ar6-2025-fossil-ch4-gwp100"
    ],
    "factorSubjects": [
      "CO2",
      "CH4-fossil"
    ],
    "outputUnit": "kg CO2-eq per specified 100 m2 / ten-year service",
    "sourceId": "src-case-ipcc-ar6-wgi-errata-2025-10-07",
    "sourceStatus": "official indexed full-table text inspected; direct source bytes and visual PDF unavailable (403 / screenshot failure); original-PDF SHA-256 remains null",
    "reportedCH4Uncertainty": "28.1 ± 10.4; not propagated in this one-parameter example; no interpretation of the ± statistic claimed here",
    "scope": "Fixed selected factor version and 100-year pulse metric; not a universal current reporting default; not observed local injury, temperature or endpoint damage"
  },
  "uncertainty": {
    "parameter": "theta",
    "meaning": "Unknown fixed fossil CO2 inventory intensity of the one shared electricity supply model, conditional on this exercise's stationary supply scenario",
    "unit": "kg CO2/kWh",
    "closedRange": [
      "0.1",
      "0.5"
    ],
    "displayPoint": "0.3",
    "sharedRelation": "Exactly the same theta applies to both alternatives and both substrate scenarios; it is not two independent unknowns",
    "probability": null,
    "interpretation": "Epistemic bounded parameter exercise, neither individual variability nor an estimated population mean; not a distribution, sampling interval, or statistical test"
  },
  "comparison": {
    "estimand": "Delta_S(theta)=I_B,S(theta)-I_A,S(theta), characterized indicator difference for one whole specified service under substrate S and a common theta",
    "tolerance": "4",
    "toleranceUnit": "kg CO2-eq per 100 m2 / ten-year service",
    "toleranceStatus": "AUTHOR-INVENTED predeclared didactic decision criterion; no empirical or stakeholder endorsement; deliberately coarse so robust tolerance and unresolved sign can coexist",
    "strictOrdering": "B lower only if all admissible Delta<0; A lower only if all admissible Delta>0",
    "boundedEquivalence": "For this one metric/model only: all admissible |Delta|<=4; evaluate paired Delta directly, never marginal-interval overlap",
    "predeclaration": "This published version fixes the author-invented tolerance and predicates as part of the teaching specification; it is not a preregistered experiment or stakeholder-endorsed criterion."
  },
  "scenarios": {
    "smooth": {
      "version": "1.0.0-S0",
      "initialCondition": "Smooth sound substrate already usable by both paints",
      "demands": {
        "paintA": [
          "10",
          "0",
          "0",
          "0"
        ],
        "paintB": [
          "0",
          "6",
          "0",
          "0"
        ]
      }
    },
    "rough": {
      "version": "1.0.0-S1",
      "initialCondition": "Rough sound substrate: A stipulated tolerant, B requires one preparation treatment over all 100 m2 before coating; same final service",
      "demands": {
        "paintA": [
          "10",
          "0",
          "0",
          "0"
        ],
        "paintB": [
          "0",
          "6",
          "100",
          "0"
        ]
      },
      "changed": [
        "B preparation final demand becomes 100 m2",
        "P-P becomes active",
        "B electricity activity rises 30 to 50 operations",
        "B inventory and indicator change"
      ],
      "heldFixed": [
        "all A entries",
        "paint B mass and durability",
        "A and B technology coefficients",
        "shared theta",
        "factor version",
        "service denominator",
        "tolerance"
      ]
    }
  },
  "priorExampleRelationship": "A new acyclic four-process case. The earlier two-process A/B feedback case retains fictitious product/emission identities and its 50/19 kg result. No emission identity, coefficient or factor is transferred from it.",
  "countercase": {
    "massKg": "6",