TianGong LCA Knowledge Base Home
Appendices

Contents · Full Text & Print

Appendix C Numerical Reconstruction of Climate Metrics

Recalculate the carbon dioxide impulse response function and its time integral against published table values, verify displayed-precision effects, and test the sensitivity of selected historical-code outputs to time-step size.

C.1 Reference Response

The multi-model intercomparison by Joos et al. (2013) defines a shared reference experiment for the carbon dioxide (CO₂) impulse response function. Background atmospheric CO₂ is raised to 389 parts per million (ppm) and held constant. In paired emission-driven runs, researchers inject a 100 gigatonnes of carbon (GtC) pulse in 2015 and subtract a matching control run to isolate the pulse-induced perturbation. The reported "per-kilogram response" is therefore a normalized output of this prescribed experiment, with 2015 as the pulse year and 389 ppm as the background state. Because the reference response is conditional on that experimental protocol, it cannot be treated as a forecast for arbitrary future product emissions.[1]

Because Joos et al. (2013) publish the fitted parameters explicitly, the reference response can be reconstructed directly. Letting R(t) denote the fraction of an emission pulse remaining in the atmosphere t years after release, the fitted function takes the form R(t) = a₀ + Σ aᵢ exp(−t/τᵢ). In the selected multi-model row of Table 5, the constant term is a₀ = 0.2173, and the three exponential weights 0.2240, 0.2824, and 0.2763 pair with time constants of 394.4, 36.54, and 4.304 years, respectively. The weights sum to 1, ensuring R(0) = 1, and the fit is defined over the paper's specified domain of 0 to 1,000 years after emission.[2]

Integrating this fitted function term by term yields I(H) = a₀H + Σ aᵢτᵢ[1 − exp(−H/τᵢ)]. Using the printed parameters, the remaining fraction at year 100 is R(100) = 0.409428, and the cumulative integral from 0 to 100 years is I(100) = ∫R(t)dt = 52.355389 years. In the companion figure in the main chapter, the upper curve tracks the instantaneous remaining fraction at each time point, while the shaded area beneath the curve up to that horizon represents the time integral of that fraction.[3]

At time horizons of 20, 100, and 500 years, this fitted function integrates to approximately 14.242, 52.355, and 183.638 years, corresponding to the values of 14.2, 52.4, and 184 years displayed in Table 4 of Joos et al. (2013). This reconstruction verifies the published fit and its rounding alignment, but it does not regenerate the underlying trajectories of individual Earth system models. Likewise, inter-model spread cannot be transferred directly as a confidence interval for an arbitrary product inventory. The response-and-integral figure in the main chapter plots this fit so that the shaded area in the upper panel matches the corresponding horizon value in the lower panel.[4]

For plots of the impulse response and its cumulative integral, see Responses and Metrics in Climate Equivalence.

C.2 Displayed Precision

Recalculating the absolute global warming potential (AGWP) from the fitted integral tests how closely printed inputs reproduce published table entries. Multiplying the 100-year integral by the radiative efficiency of 1.77 × 10⁻¹⁵ W m⁻² kg⁻¹ given in the Joos et al. (2013) table footnote produces 92.669 × 10⁻¹⁵ W m⁻² yr kg⁻¹, whereas Table 4 reports a mean of 92.5 × 10⁻¹⁵ W m⁻² yr kg⁻¹. The two figures are close without matching to every digit, and the exact source of the small gap remains unidentified. Both the parameter-based recalculation and the authors' reported value should therefore be retained separately; even if an adjusted parameter can be back-solved to eliminate the difference, that does not establish it as the authors' undisclosed original input.[5]

Relative metrics can also fail to reproduce digit for digit from printed absolute values. In the corrected supplementary table of the Intergovernmental Panel on Climate Change (IPCC) Sixth Assessment Report (AR6) Working Group I (WGI), generic methane has an AGWP100 of 2.43 pW m⁻² yr kg⁻¹ and the CO₂ reference is 0.093 pW m⁻² yr kg⁻¹; their direct quotient is 26.129, yet the relative-metric column displays 26.2. If each printed entry is explicitly assumed to carry a rounding band of half a unit in the last displayed place, the columns are mutually consistent. This check diagnoses arithmetic compatibility among displayed numbers; it does not estimate a confidence interval for physical climate effects.[6]

C.3 Historical Code

Re-running historical author code verifies whether a specific source snapshot reproduces the values printed at the time. The 2021 Zenodo archive of the IPCC AR6 WGI Chapter 7 author code and the later GitHub snapshot—which added the carbon-feedback functions and metric-generation workflow—contain different routines. On its 0.1-year time grid over the selected scope, the later snapshot yields a generic methane 100-year global warming potential (GWP100) of 27.859214 and a 100-year global temperature change potential (GTP100) of 5.377065, matching the pre-errata supplementary table. Because this run includes warming-driven carbon-cycle feedbacks but does not execute the fossil oxidation or biogenic uptake pathways for methane's own carbon, it reproduces neither the two main-table methane rows nor the 2025 errata.[7]

Refining the time step reveals how sensitive the numerical output is to discretization. Holding all physical parameters constant and halving the feedback-convolution step from 0.1 years to 0.05 years increases GWP100 by approximately 0.079728 and GTP100 by approximately 0.099951. Agreement on the original discrete grid confirms internal consistency for that code version, whereas establishing full numerical convergence requires testing progressively finer grids. Nor does the difference between these two step sizes explain the official errata or measure climate-parameter uncertainty. The value of numerical reconstruction lies in specifying exactly which object is reconstructed and keeping each diagnostic check within its own scope.[8]

For metric versions and their comparative uses, see Inventory Comparisons in Climate Equivalence.

Notes

  1. Source statement. 100 GtC CO₂ pulse and control runs under the prescribed background protocol of Joos et al. (2013).

    Caveats: Several participating models did not submit full-length control or pulse runs, as documented separately in the paper and its supplementary protocol; only the published multi-model fit is used here.

  2. Source statement. Multi-model CO₂ impulse response fit from Joos et al. (2013), Table 5, over the 0–1,000-year domain.

    Caveats: The constant term a₀ is a fitting component over this finite 1,000-year horizon and does not assert that a fixed fraction of emitted carbon remains permanently in the real atmosphere.

    Download calculation input (v1.0.0)

  3. Calculation. Instantaneous remaining fraction and analytical time integral reconstructed from the printed parameters of the Joos et al. (2013) fit.

    Premises referenced (1)
  4. Calculation. Comparison of analytical integrals from the published fit against displayed values in Joos et al. (2013), Table 4.

    Premises referenced (2)
  5. Calculation. Recalculation from displayed parameters in Joos et al. (2013) versus Table 4 reported values, without back-solving undisclosed precision.

    Caveats: The exact source of this small discrepancy is unidentified; displayed parameter precision and physical uncertainty are distinct issues.

    Premises referenced (2)
  6. Calculation. Displayed-precision check for the generic methane AGWP100 ratio in the corrected IPCC AR6 WGI supplementary table.

    • IPCC AR6 WGI Errata — Version 7 October 2025 (Version 7 October 2025; pp. 2–5 document corrections not yet merged into the published text; pp. 18 and 25 distinguish FGD corrections already incorporated prior to publication) — Replacement Table 7.SM.7 (first page: CO₂ reference, methane and other selected rows, and footnotes), p. 5 (PDF p. 5)
    Premises referenced (2)
  7. Calculation. Selected native routines (0–100 years) from the post-release IPCC AR6 WGI Chapter 7 author-code snapshot for the historical generic methane column.

    Caveats: Only selected routines over 0–100 years were executed; this does not replay all original models, full notebooks, figures, other gases, or uncertainty ensembles.

    Premises referenced (3)
  8. Calculation. Numerical grid sensitivity between 0.1-year and 0.05-year time steps under fixed physical parameters.

    • IPCC WGI AR6 Chapter 7 — Author metrics code, fixed post-release snapshot (GitHub pinned commit 2f948c862dbc158182ba47b863395ec1a4aa7998 (2022-09-27); metric generation code added 2021-09-22 and methane response component data added 2021-11-03, both postdating Zenodo v.1.0) — src/ar6/metrics/gasser.py, lines 6–14, 33–60
    • IPCC AR6 WGI Errata — Version 7 October 2025 (Version 7 October 2025; pp. 2–5 document corrections not yet merged into the published text; pp. 18 and 25 distinguish FGD corrections already incorporated prior to publication) — Section 7.6.1.1 radiative efficiency erratum and full replacement Table 7.15 (header, caption, and selected rows), p. 3 (PDF p. 3)
    Premises referenced (1)

On this page