TianGong LCA Knowledge Base Home
Part II Services and Inventories

Contents · Part II · Services and Inventories · Full Text & Print

Chapter 6 Functional Reference

Define the service to be delivered first, then determine how much product each alternative requires and what basis process records are scaled against.

6.1 Service Requirements

Before comparing two paints for a wall, an analyst must state what condition the wall is expected to reach and how long that condition must last. Mass in kilograms records how much paint is purchased, but coverage and protective performance must be specified separately. The 2010 International Reference Life Cycle Data System (ILCD) Handbook defines a functional unit through four elements: what is delivered, how much, how well, and for how long. This chapter groups those four elements as the service requirement. Fixing them first makes it possible to determine how much of each paint is needed for a fair comparison.[1]

Identical dimensions do not guarantee an identical service. The 2006 U.S. Environmental Protection Agency (EPA) guidance illustrates this with thermal insulation: two materials of the same area and thickness can differ substantially in thermal resistance. If the goal is to reduce heat flow, the comparison must first align the required reduction in heat transfer. This example serves as a pedagogical illustration in the guidance; the thermal performance of real products still requires empirical product data.[2]

Reporting environmental burdens "per use" leaves the comparison incomplete unless it is clear whether both options perform the same task. A service requirement should specify who uses the product, what level of performance is required, how long that performance lasts, and which differences the study accepts. Two alternatives may differ in technical attributes so long as the analyst explains how their relevant service is aligned. The ILCD Handbook also discusses comparing partially comparable options, provided that the underlying judgments and preferences are stated explicitly. Whenever an accepted difference can affect the conclusion, the main text must explain why it was accepted.[3]

How a service is defined determines which activities enter the inventory. The 2006 EPA guidance compares bar soap and liquid soap by first asking how much of each is needed for an equivalent hand-washing event; matching mass or volume alone cannot answer that question. If the liquid soap also provides moisturizing benefits, the guidance asks two follow-up questions: whether moisturizing is relevant to the study goal, and whether consumers actually realize that benefit. When both conditions hold, the bar-soap alternative must account for adding hand lotion so that it is compared against a system delivering both cleansing and moisturizing.[4]

Shifting the service from "hand-washing" to "hand-washing plus moisturizing" can pull previously omitted products, packaging, or use-phase activities into the inventory. The analyst must inspect and include those activities rather than merely changing the denominator of the original calculation. The soap example states clear conditions for expanding the boundary; whether other secondary functions should be included still depends on the specific study purpose and how those functions are delivered.[5]

In the wall-coating setting, the analyst first specifies the performance the coating must deliver and then determines how much of each concrete product is needed to achieve it. That conversion depends on spreading rate, service life, use conditions, and maintenance schedules. Only with those conditions specified can a service requirement be translated into the product or service quantities required by each alternative.[6]

Suppose two paints satisfy the same coating and protection requirements over a single maintenance period for a 10 m² wall, requiring 0.20 kg/m² of Paint A or 0.25 kg/m² of Paint B. Multiplying area by application rate yields 2.0 kg of Paint A and 2.5 kg of Paint B. Equivalent performance is an explicit premise of this calculation, and multiplication shows only how much product is needed under those assumptions. If environmental results are reported per kilogram of paint, one must still verify coverage, durability, and maintenance schedules before scaling to the same service.[7]

6.2 Reference Objects

Once the required quantity of each paint is known, the next question is what basis the other quantities in the process data are expressed against. In Part 2a (§2.3.4) of the 2001 CML (Institute of Environmental Sciences, Leiden University) operational guide, the reference flow of an alternative is expressed as the wall area covered by a given paint, while the required paint volume is recorded in the process data. Here the service requirement states the desired wall condition, area provides the quantitative reference for the alternative, and paint volume enters the process dataset—so the reference flow is expressed in terms of area.[8]

The 2010 ILCD Handbook (§6.4.1) similarly notes two conventions: a reference flow may be expressed directly in terms of the functional unit or as a quantity of product. Which convention is chosen depends on the nature of the product, the intended use of the data, and how the software models the system. Under either convention, the dataset must make clear how all other inputs and outputs are scaled relative to the reference. Even a label reading "1 kg of product" requires checking whether the dataset describes producing 1 kg of product or uses 1 kg of product to represent the function delivered by an alternative.[9]

When reading the CML and ILCD guides side by side, a practical sequence is to identify the service requirement first, then check what quantity serves as the alternative's reference, and finally inspect the process records needed to deliver it. Both guides use the term "reference flow," yet whether two reference flows are interchangeable depends on what each measures, what role it plays in the study, and whether both can be converted under identical conditions. This sequence is the monograph's synthesis for comparing usage across the two guides.[10]

In an ILCD Format 1.1 process dataset, the quantitativeReference section specifies the basis to which inputs and outputs are scaled. Its type may be a reference flow, a functional unit, another parameter, or a production period. When a production period is selected, the reference is the operating time span represented by the dataset. Seeing this field therefore never justifies assuming that the dataset is automatically normalized to 1 kg of product.[11]

When the type is set to Reference flow(s), the referenceToReferenceFlow field points to one or more input or output exchanges within the dataset that serve as its reference. This field records an internal pointer to exchanges in the dataset; the product's functional performance is documented separately in text.[12]

To inspect functional performance in the same format, one checks the functionalUnitOrOther field. It can record a quantity, name, property or quality, and unit without pointing to any single flow. Even when a dataset uses a reference flow as its quantitative reference, it may also record a functional unit alongside it, allowing one file to store both exchange pointers and performance descriptions. This describes what ILCD Format 1.1 permits a dataset to store; how the International Organization for Standardization (ISO) or other methodologies formally define a functional unit must be checked in their own governing texts.[13]

Detailed field definitions appear in the Quantitative reference section of ILCD Format 1.1 Documentation — Process data set.

6.3 Comparison Conditions

If Paint B in the 10 m² example also requires a maintenance recoating during the same period, the initial 2.5 kg reflects only the original schedule. One must specify what the maintenance operation entails and recalculate material inputs before assessing environmental performance; if the required surface performance itself changes, the comparison problem must be reframed altogether. Footnote 39 to the ILCD paint example similarly cautions that recoating may require stripping the old layer or applying a future paint formulation. Which processes maintenance alters must be established before multiplying material quantities.[14]

Wall Service Comparison constructs a separate 100 m² wall maintained over ten years to show how performance, service life, and maintenance determine process quantities and shape impact indicators. Each worked example rests on its own explicit assumptions.

Even when a dataset stores both reference-exchange pointers and performance descriptions, the analyst must verify which activities the model actually uses to deliver the service. One can trace product identity, quantity, and unit through the exchange pointer and then inspect the evidence supporting performance and dosage. Product Category Rules (PCR) define declared units in different ways, and software tools represent multi-product demands differently. Both pieces of information may appear in the data record, but whether the model actually applies them must be verified in the modeled processes and links.[15]

Establishing service comparability is only the first check; the systems delivering that service must also be audited. In discussing assertions of environmental superiority or equivalence, CML 2001 paraphrases ISO requirements on system boundaries, data quality, allocation, and impact assessment. ILCD 2010 further details how to check consistency across scenarios, service lives, maintenance, data, and modeling, noting that uncertainty and the set of included impact categories constrain what can be concluded. Even when two alternatives deliver a comparable service, the results may support a difference only on a single indicator; any overall claim must state the impact categories, models, and conditions used.[16]

This monograph divides a comparative assessment into three distinct judgments: how the service requirements of the alternatives are aligned and which differences are accepted; how the model's boundaries and data represent the processes delivering that service; and how strong a difference claim the final results can support. The remainder of this chapter places the first judgment across four major methodological and database frameworks to clarify where functional units, declared units, activity-level reference products, and comparability gates align—and where they diverge.[17]

Placed side by side, the ILCD Handbook, the European Union Product Environmental Footprint (PEF) method, the Greenhouse Gas Protocol (GHG Protocol) Product Standard, and the ecoinvent v3 Data Quality Guideline all agree that comparing alternatives requires fixing a verifiable quantitative benchmark and separating the service delivered from the physical product quantity needed to deliver it. Yet that consensus holds chiefly for final-product comparisons where all four elements (what, how much, how well, how long) are explicit and boundaries are symmetric. Once a study enters activity-level data modeling, intermediate products with undetermined end uses, service-life rounding, or public comparative assertions, the four frameworks diverge sharply in both division of labor and admissibility thresholds.[18]

The first structural divergence lies in the analytical layer at which the reference operates. ILCD, PEF, and the GHG Protocol all define service-oriented functional units and reference flows at the study level. By contrast, the ecoinvent v3 Data Quality Guideline operates at the unit-process activity level: rather than prescribing a study-level functional unit, it defines the reference product (or determining product in consequential modeling) as the output whose change in demand directly scales the activity, and records waste-treatment services as negative physical reference products representing the material received. A database reference product therefore specifies only how an individual process is scaled and linked; it cannot stand in directly for a study-level functional unit across competing alternatives.[19]

The second divergence concerns intermediate products whose downstream uses are not yet fixed. For semi-finished goods or materials entering diverse end uses, both ILCD (such as 1 kg of steel coil) and PEF allow a declared unit accompanied by technical specifications, and ILCD §6.4 explicitly states that a declared unit is not a functional unit: it may be used to compare alternative production routes for the same material, but not to compare different materials on an equal-mass basis. The GHG Protocol Product Standard avoids the term "declared unit" altogether and introduces an overarching "unit of analysis": final products must use a functional unit as their unit of analysis, whereas intermediate products with undetermined downstream functions use a reference flow directly under a cradle-to-gate boundary while disclosing the excluded use and end-of-life stages.[20]

The third divergence governs how service requirements are converted into reference flows and how non-functional attributes are handled. ILCD separates "obligatory properties" (binding technical and regulatory requirements) from "positioning properties" (market features such as comfort or appearance), and illustrates the conversion in Table 4 for exterior wall paint over a ten-year protection period: solvent-based Paint A (two coats, recoated after five years) requires a reference flow of 6.5 L (with footnote 39 noting old-coat removal and future coating conditions), whereas water-based Paint B (one coat lasting ten years) requires 3.8 L. EU PEF illustrates the four elements with decorative paint (protecting and decorating 1 m² of substrate for 50 years at a minimum hiding power of ≥ 98%) and adds two binding rules: the number of products needed to meet the specified service life must in principle be rounded up (unless justified otherwise), and any subjective or non-quantified attributes omitted from the functional unit must be disclosed and justified.[21]

The fourth divergence concerns whether fixing a functional unit authorizes public comparative assertions. Even when two alternatives are converted to reference flows under identical four-element definitions, the permissions granted by each framework differ sharply. EU PEF (Annex I §1) allows cross-product comparisons and public comparative assertions only when the study strictly follows an applicable Product Environmental Footprint Category Rules (PEFCR) document. The GHG Protocol Product Standard states in Appendix A that, as written, it supports longitudinal performance tracking of the same product over time rather than ISO 14044 cross-product comparative assertions; comparing different products requires additional product rules, equivalent boundaries, and third-party assurance. ILCD requires comparative studies to verify consistency in scenarios, service life, maintenance, data quality, and modeling alongside functional-unit alignment.[22]

Table: Cross-Framework Comparison of Functional Units, Reference Flows, Intermediate Products, and Comparative-Assertion Boundaries

Framework & Open-Access SourceCore Reference Layer & ElementsHandling of Intermediate ProductsConversion Rules & Non-Functional AttributesComparability & Comparative-Assertion Gates
ILCD Handbook (2010, §§6.4, 6.10)Study-level functional unit (what, how much, how well, how long) and reference flowUses a declared unit (e.g., 1 kg steel coil), explicitly stating it is not a functional unitDistinguishes obligatory from positioning properties; Table 4 converts ten-year wall paint to 6.5 L vs 3.8 LComparative studies must also verify consistency in scenarios, service life, maintenance, data, and modeling
EU PEF (Commission Recommendation (EU) 2021/2279, Annex I §§1, 3.2.1)Study-level four-element functional unit (e.g., decorative paint: 1 m², 50 years, hiding power ≥ 98%) and reference flowIntermediate products may use a declared unit (where reference flow may coincide with functional unit)Number of products for specified service life rounded up in principle; mandatory disclosure and justification of uncovered attributesCross-product comparisons and public comparative assertions permitted only when strictly following an applicable PEFCR
GHG Protocol Product Standard (2011, Ch. 6, §7.3.7, Appendix A)Study-level overarching "unit of analysis" and reference flow; final products use a functional unit as unit of analysisDoes not use "declared unit"; uses reference flow directly as unit of analysis with cradle-to-gate disclosureAllows setting functional unit or reference flow first; requires preventing fractional-product distortionAs written, supports same-product performance tracking over time only; does not support ISO 14044 comparative assertions
ecoinvent v3 Data Quality Guideline (2013, Ch. 3, §4.1.2, §§14.1–14.3)Unit-process activity-level determining reference product (waste-treatment services recorded as negative reference products)Intermediate products link by default to local markets via unit-process reference productsDoes not prescribe study-level service-life rounding or positioning properties; leaves these to downstream studiesProvides activity-level data linkage only; does not by itself establish service equivalence

This comparison also marks the epistemic boundary of functional reference: standard clauses can prescribe how to formulate a functional unit, declared unit, or reference product and set admissibility gates, but they cannot substitute for empirical evidence on actual service life, aging and degradation, user behavior, or non-functional substitution preferences. Treating a calculated reference flow, rounded product count, or activity-level reference product as proof of real-world market equivalence still requires independent engineering and use-phase evidence. Furthermore, because the full texts of ISO 14040 and ISO 14044 are copyright-protected and paywalled, open-access comparisons do not quote their clauses verbatim; exact compliance requirements must be verified against licensed ISO texts. Having fixed the functional reference and reference flow, the next chapter turns to the second judgment: given how much product must be delivered, how a linear process network determines the supply activities required to deliver it.[23]

Formal definitions and primary sources for the two core terms appear under Functional unit and Reference flow.

Continue to the next chapter: Process Networks.

Notes

  1. Interpretation. Entry point for service-based comparisons constructed from the ILCD 2010 functional-unit specification

  2. Source statement. Historical context from the named guidance excerpt; does not substitute for current standards or product-level verification

    Caveats: Pedagogical examples do not provide empirical performance or environmental comparison evidence for real products.

  3. Interpretation. Conditional interpretation of service alternatives; partially comparable options still require explicit judgments and preferences

    Caveats: Discussion of partially comparable options does not waive specific comparative-assertion rules, Product Category Rules, or other applicable requirements.

    Premises referenced (2)
  4. Source statement. Historical context from the named guidance excerpt; does not substitute for current standards or product-level verification

  5. Interpretation. Inference from the conditional pedagogical example; does not claim that every additional function requires system expansion

    Premises referenced (1)
  6. Interpretation. Interpretive framework linking functional specification to reference flows

    Caveats: Conversion can depend on performance, service life, and use conditions; a single product quantity cannot substitute for those premises.

    Premises referenced (2)
  7. Calculation. Author-constructed pedagogical coating-maintenance example; 0.20 × 10 and 0.25 × 10

    Caveats: Numerical values are explicit assumptions, not measured data or product performance claims; environmental results still require separate calculation.

    Premises referenced (1)
  8. Interpretation. Alternative reference basis and process data in the CML 2001 Part 2a §2.3.4 paint example

  9. Interpretation. Use-dependent expression of reference flows in ILCD 2010 §6.4.1

  10. Synthesis. Author synthesis comparing usage in CML and ILCD; not a unified formal terminology definition

    Premises referenced (2)
  11. Source statement. ILCD Format 1.1 process dataset specification

  12. Source statement. ILCD Format 1.1, eDoc 1-1-4-16 and 1-1-4-17

  13. Source statement. Quantitative reference documentation in ILCD Format 1.1

    Caveats: This explains the meaning of the format documentation, not a unified definition across ISO standards or all LCA methods.

  14. Interpretation. Condition change in the author's 10 m² pedagogical example, contextualized by the ILCD maintenance note

    Caveats: Does not provide empirical conclusions about real paint performance, recoating frequency, or environmental superiority.

    Premises referenced (2)
  15. Interpretation. Interpretive boundary among data format, functional description, and model execution; makes no claim about specific software behavior

    Caveats: What a data format can record does not determine solver behavior; specific implementations require independent evidence.

    Premises referenced (4)
  16. Synthesis. Bounded synthesis of CML comparative-assertion requirements and ILCD comparative-study conditions

    Caveats: Selected guidance excerpts do not substitute for verifying the authoritative ISO text, the modeling provisions cited by ILCD, or full study compliance.

    Premises referenced (2)
  17. Analytical proposal. Analytical proposal dividing comparative studies into service, model, and result layers; not an added formal standard phase

    Premises referenced (1)
  18. Synthesis. Shared premises and divergence points across ILCD, PEF, GHG Protocol, and ecoinvent v3 on functional reference

    Premises referenced (3)
  19. Synthesis. Layer separation between study-level functional units and activity-level determining reference products in ecoinvent v3

    Premises referenced (3)
  20. Synthesis. Terminological and methodological divergence between declared units in ILCD/PEF and reference-flow units of analysis for intermediate products in the GHG Protocol

    Premises referenced (2)
  21. Synthesis. Comparison of ILCD obligatory/positioning properties and Table 4 conversion against PEF rounding-up and mandatory disclosure of uncovered attributes

    Premises referenced (3)
  22. Synthesis. Divergent admissibility gates for cross-product comparisons and public comparative assertions across PEF, GHG Protocol, and ILCD

    Premises referenced (3)
  23. Synthesis. Empirical limits of cross-framework functional-reference comparisons and citation boundaries for paywalled ISO standards

    Premises referenced (5)

On this page