TianGong LCA Knowledge Base Home
Part II Services and Inventories

Contents · Part II · Services and Inventories · Full Text & Print

Chapter 8 Flows, Exchanges, and Boundaries

Do two records with the same name and unit answer the same question? Trace objects, environmental interfaces, treatment activities, quantitative references, and characterization starting points to determine when different representations hold.

8.1 System Boundaries and Flow Identity

When a factory sends wastewater past its gate, the stream has left the facility without necessarily entering a natural water body. If the wastewater travels to a treatment plant, leaving the factory gate crosses an interface between two technical processes; only the pollutants discharged into a river after treatment cross the boundary between the technical system and the environment. Defining a system boundary therefore requires separating two distinct questions: which processes the study includes, and which exchanges the model treats as direct exchanges with the environment. The first question determines how far the study traces the supply and disposal chain; the second determines what enters the environmental inventory.[1]

International Organization for Standardization (ISO) standard ISO 14040:2006 defines an elementary flow as material or energy drawn directly from the environment without previous human transformation, or released directly into the environment without subsequent human transformation. Even when different frameworks or software manuals share the label "elementary flow", the shared label does not guarantee identical classification criteria; each system's boundary rules must still be verified. Product systems may also exchange product flows with other product systems; the standard does not classify every flow crossing a study boundary as an elementary flow. ISO 14044:2006 permits omitting inputs, outputs, or unit processes only if they do not significantly change the overall conclusions of the study, and requires stating the criteria and effect of exclusions and cut-offs. Failing to link wastewater treatment because data are unavailable leaves an open technical gap in the model—it does not justify relabeling the entire wastewater stream as a specific pollutant already discharged into a river.[2]

8.1.1 Different Boundaries for Landfills and Agricultural Land

Even after separating those two questions, different methodological frameworks do not draw the environmental interface in the same place. For unmanaged landfills, the 2001 operational guide from the Institute of Environmental Sciences, Leiden University (CML) treats the landfill itself as part of the environment, allowing the bulk waste stream entering it to be recorded as an emission. By contrast, the 2010 International Reference Life Cycle Data System (ILCD) Handbook requires modeling the release of specific substances and related environmental interventions from the waste. That rule extends even to a battery discarded in nature: although the battery physically lies in the environment, the model retains it on the technical side and tracks the substances it releases into soil, water, and air. Both guides thus place the inventory interface at different points for the same physical situation.[3]

That boundary difference changes the object that impact characterization receives. Kilograms of bulk waste cannot directly substitute for kilograms of a specific metal leached into water; which characterization factor applies depends on the exact substance and environmental compartment from which the factor begins. ILCD disaggregates complex waste streams so that inventory flows connect cleanly to corresponding impact models, yet composition, release pathways, and time horizons still require evidence. CML likewise discusses long-term emissions and temporal assumptions. Being more disaggregated or published later does not by itself prove that one guide predicts emissions from a real landfill more accurately than the other.[4]

Divergences on agricultural land likewise stem from where each model draws the process boundary. The CML 2001 guide places agricultural activities inside the economic system while leaving natural soil on the environmental side, and discusses pesticide emissions after subtracting the fraction removed with the harvested crop; horticulture on artificial substrates is treated differently, and the guide allows other consistent boundary choices to be discussed. The ILCD 2010 Handbook generally places managed agricultural land on the technical side and distinguishes the applied amount from environmental interventions such as spray drift, volatilization, runoff, and leaching. Amounts applied to a field, removed with the harvest, and entering water bodies therefore cannot substitute for one another simply because all three are measured in kilograms.[5]

The environmental interface is therefore a conditional modeling rule rather than a blanket slogan. For certain heavy metals and persistent organic pollutants remaining long-term in soil, ILCD separately requires recording emissions to soil while avoiding double counting with erosion transfers; it also specifies dedicated rules for radioactive waste, underground disposal, and qualifying aggregate indicators. Where the chosen impact method covers physical interventions caused by litter, those interventions must also be recorded. Consequently, "managed land belongs to the technical system" cannot be compressed into "agricultural land has no soil emissions", nor can "model through to environmental interventions" be compressed into "every inventory record must be a single chemical substance".[6]

8.1.2 Object Definitions and Process Records

Once concepts enter data files, one must also separate the defined object from a concrete transfer into or out of a process. ILCD Format 1.1 uses a Flow data set to define a flow's identity and measurement properties—along with compartment categorization for elementary flows—and separately references it via an exchange inside a Process data set to record direction and amount for that process. The same flow can appear in exchanges across multiple processes or multiple times within a single process. The flow's default measurement property (such as mass) specifies what physical quantity measures it; a given exchange's amount specifies how much enters or leaves in that process record. An object definition does not predetermine the quantity or role of any individual exchange.[7]

First identify the object sitting on the arrow. The openLCA 2 manual divides flows into three types: elementary flows, product flows, and waste flows. Material or energy drawn from the natural environment without previous human transformation—such as extracted crude oil—can be recorded as an elementary flow, as can material or energy released into the environment without subsequent human transformation, such as emissions to air. Product flows and waste flows must be identified in light of their role in a process; the manual notes that waste paper sent for recycling can also be modeled as a product flow.[8]

Whenever a process uses or generates a flow, it requires a separate exchange entry. In openLCA's Inputs/Outputs table, each exchange references a defined flow and specifies its amount, unit, and direction as an input or output. A single defined flow can be referenced by many exchanges across many processes.[9]

Water makes this two-layer distinction concrete. The flow definition specifies what kind of object water is; the exchange records how much water a given factory uses, in what unit, and on which side of the process. Even when two factories reference the exact same flow object, each retains its own exchange quantity and role. When auditing an inventory, identify the flow object first and then return to the specific exchange in which it occurs.[10]

ISO's conceptual terms for elementary flows and product systems, ILCD Format 1.1 flow data sets, and flows referenced by exchanges in openLCA operate at different layers. Conditional mappings can be built across them, but shared names do not permit blind field-by-field substitution. For instance, ILCD Format 1.1 also includes an "Other flow" type, whereas the openLCA 2 manual presents three flow types here. A different number of enumerated categories reflects representational scope rather than competing theories of natural processes; any concrete conversion must still verify the exchanged object, its role, and its links.[11]

Two records with the same name and unit can still represent different environmental flows. In the Environmental Footprint (EF) 3.1 reference package, two elementary flows both named "aluminium (iii)" are measured by mass with the reference unit kg, yet one refers to agricultural soil and the other to long-term unspecified water, with distinct data set identities. In the inspected freshwater ecotoxicity method, the two flows correspond to a positive factor and a zero entry respectively; one cannot merge them by name first and then pick either factor arbitrarily. Agricultural soil also contains a separate record named "aluminium" whose factor happens to match the agricultural-soil "aluminium (iii)" entry, but that numerical match does not make the two identities interchangeable in other methods or uses. Distinct identities may still be aggregated for an explicit purpose, provided the preserved quantity, composition, and mapping basis are documented.[12]

A flow definition specifies what a record represents; process linking determines who must supply the activity. The sections below first trace how treatment activities enter calculation, then examine how model conversions preserve quantitative demands, and finally return to the starting points and factors of inventory characterization. Allocation settings are used here to test the conditions for comparing representations; burden-partitioning rules themselves are examined in Reading System Models.

8.2 Material Direction and Treatment Activities

A flow's identity also depends on the question being asked. ISO 14040:2006 defines waste as substances or objects that the holder intends or is required to dispose of, whereas the CML 2001 guide defines economic flows to encompass exchanges of positive, zero, or negative value, distinguishing waste for treatment from products within that context. Residual economic value alone does not settle whether an object requires disposal, and a software label of "product" does not by itself tell whether a model includes end-of-life treatment. Disposal status, traded commodity, and software flow type must each be stated separately.[13]

The direction of physical material movement and the direction of a purchased service can also diverge. When a factory hands waste to a treatment facility, it simultaneously receives a disposal service; even if that service is measured per kilogram of material treated, it does not become a physical commodity traveling in the same direction. Analyzing such exchanges through the functions that processes supply or use, Suh demonstrates that physical dimensions and net monetary payments alone cannot identify the function of an exchange. The ILCD 2010 Handbook accordingly allows accounting either as a waste output or as a treatment-service input, while recommending the material-flow direction to facilitate mass and elemental balances. That conceptual correspondence is not yet a software sign convention.[14]

Sending a batch of waste from a factory to a treatment facility takes only a single arrow on paper. To compute how much the facility treats, software must also know which processes sit at each end, how much is sent, and what reference quantity scales the treatment record. A file import may display the waste flow intact while the solver silently omits the treatment process. The bottle and injection-molding examples below trace how treatment enters calculation, and then examine which results change—and why—when the same model moves across file formats or characterization factors.[15]

Identifying an input or output still leaves open who supplies or treats it. An openLCA product system stores the link between a specific exchange and its chosen provider separately. Although an exchange may also carry a default provider field, determining which supplying process the solver will actually invoke requires checking the links saved in the product system rather than trusting the name in the default field.[16]

Once a supplying process is selected, calculation must determine how many multiples of its record are needed. A process's quantitative reference gives the input or output amount represented by one unit of that record. The product system's target amount is taken up by the reference process, while each linked supplying or treatment process takes up the demand issued by the exchange connected to it. When a process has a single reference flow and scales proportionally, dividing the demand placed on that process by its reference amount yields the activity scaling factor needed to meet that demand. Before dividing, measurement units must be harmonized and input/output direction and sign conventions applied; if the reference exchange contains a formula, it must first be evaluated under the active parameters. That scaling factor is relative to the model record's reference basis—determining how many times real equipment actually ran requires operational records.[17]

8.2.1 Two Representations of the Same Treatment Activity

For modeling waste treatment, the openLCA manual describes a convention aligned with physical movement called "material flow logic". The waste-generating process records a waste output, while the treatment process records a waste input and designates that input as its quantitative reference. When reading a treatment record under this convention, look for the reference amount on the input side.[18]

GreenDelta's bottle tutorial provides a controlled side-by-side test of both conventions. The tutorial targets openLCA 1.10; here, the archived database backup is restored into a working copy, migrated, and solved with the official openLCA 2.7.0 Java modules. The findings below describe the calculation behavior of that pinned teaching model in that module version. The tutorial text and archived database can be inspected independently; how a historical desktop patch behaved at release, or what environmental performance real bottles achieve, requires separate evidence.[19]

The bottle use process takes 1.06500 kg of filled water bottle as input, designates 0.06500 kg of "PET Bottle, disposed" (polyethylene terephthalate) as its product-output quantitative reference, and uses a second exchange referencing a different flow object to link to incineration. The reference output sets how much bottle mass the calculation represents, while the treatment exchange demands incineration of that same mass of discarded material, with its flow type and direction determined by whichever of the two conventions is used. Because those two records represent the calculation basis and the treatment demand for the same batch of bottles, their masses cannot be added together. Nor does the tutorial's exchange table fully account for the final fate of the drinking water.[20]

Under material flow logic, the use process records an output of 0.06500 kg of a waste flow, and the treatment process uses an input of 1000.00000 kg as its reference. Both recorded quantities are positive, yet one unit of the use record generates far less waste than the treatment record's reference basis. Scaling the treatment activity along the link therefore requires converting between those two quantities.[21]

The openLCA manual also describes an "opposite direction approach". Here the flow type is changed to "product", the waste-generating process records a negative input, and the treatment process records a negative output. Physical material still moves from generator to treatment facility; the software encodes that direction through the combination of flow type, input/output side, and sign.[22]

The same batch of bottles can be encoded in the opposite direction. The use process records a product input of −0.06500 kg, and the treatment process takes a product output of −1000.00000 kg as its reference. The minus sign must be read together with the input/output side at both ends to identify which process demands treatment; the physical mass of the bottles remains positive.[23]

Both reference quantities are now fixed. Setting the product system target to 0.06500 kg of reference bottle requires exactly one unit of the use record. The linked treatment activity scaling factor is 0.06500 ÷ 1000.00000 = 0.000065; dividing the two negative quantities in the opposite-direction encoding yields the exact same positive scaling factor. Both encodings demand the same amount of treatment here because reference, quantity, and link are matched item for item.[24]

Next examine how both encodings enter the balance equation. When the treatment reference and the use process's treatment exchange are assembled into the technology matrix in this case, outputs enter with their recorded sign while inputs are negated. Consequently, both the positive 1000 kg waste input and the negative 1000 kg product output produce −1000, while both the positive 0.065 kg waste output and the negative 0.065 kg product input produce +0.065. The treatment diagonal entry and off-diagonal link entry are thus identical across both unallocated models. With one unit of the use record, the treatment balance reads 0.065 − 1000 × treatment scaling factor = 0. The negative diagonal entry offsets the generated waste mass; it does not mean the facility treats negative mass.[25]

To compare two sets of records reliably, first sketch where the physical material comes from and where it goes, then align flow type, process roles at both ends, input/output side, sign, and quantitative reference. Reading minus signs in isolation mistakes a computational sign convention for a definition of waste; reading the "product" label in isolation hides the fact that the material is awaiting disposal. Checking all of these fields clarifies this example, while other software systems require inspecting their own conventions.[26]

Switching software to Brightway requires re-checking sign conventions from scratch. Brightway's documentation places process-to-product supply-chain relations in the technosphere matrix and exchanges between processes and the natural environment in a separate matrix. Positive technosphere values represent production and negative values represent consumption. Because a process can output waste without waste generation being the purpose of the process, identifying which edge carries the functional role still requires checking Brightway's node and edge conventions.[27]

In Brightway, the "input" and "output" fields specify how product or biosphere nodes connect to process nodes within its graph schema. Interpreting which way physical material moves requires knowing that schema's definitions; sharing the same English words with another software tool does not allow transferring that tool's direction rules.[28]

Even when activity levels are identical, impact scores can diverge if allocation settings differ. The tutorial's incineration process involves waste treatment alongside electricity and steam outputs; allocation determines what share of the process's burden each function carries, with economic allocation deriving shares from quantities, costs, and revenues. In the archived database, the material-flow-logic treatment process defaults to economic allocation, whereas the opposite-direction process does not carry the same setting. To avoid conflating burden partitioning with representational equivalence, the encoding comparison here explicitly fixes allocation to none (NONE), while evaluating economic allocation separately.[29]

To isolate the two encodings, target demand, background data, links, and the no-allocation setting are held constant. Once the two pairs of use processes, treatment processes, and treatment flows are matched by role, the technology supply-demand matrix, the per-unit inventory matrix, and the flow-to-impact characterization matrix are identical. Both runs contain 10 activity coordinates, 435 inventory coordinates, and 11 impact categories, with totals matching within floating-point tolerance. For example, 100-year global warming potential (GWP100a) is approximately 0.369674399 kg CO₂ eq (kilograms of carbon dioxide equivalent) in both runs. Both the matrix correspondence and the score agreement remain strictly bounded to this coordinate set and configuration.[30]

Outside openLCA's two field encodings, the bottle quantities can also be written on paper using a service-direction balance. Let U be the use-activity scaling factor and H be the treatment-activity scaling factor: the use process inputs a disposal service measured by 0.065 kg of waste treated, and one unit of the treatment facility outputs the same service measured by 1000 kg of waste treated, giving the service balance −0.065U + 1000H = 0. Here kg measures the mass of waste treated by the service, not a physical mass carried by the service itself. Written in the material direction, the balance is 0.065U − 1000H = 0; at U = 1, both equations yield H = 0.000065. If the same row also carries an external delivery or absorption demand, reversing direction requires negating the right-hand side as well. This author derivation does not execute a new service model and is not the same thing as openLCA's negative-product fields above: the conceptual direction of a service flow and how software interprets flow type, side, and sign must be verified separately. Whenever the facility, waste composition, linking, or allocation changes, multiplying a row by −1 no longer establishes equivalence.[31]

8.2.2 Activity, Inventory, and Category Results

To verify directly that incineration participated in the calculation, check a specific substance emitted to freshwater by the treatment process. In the tutorial figure, the treatment record—referenced to 1000 kg of waste—emits 0.00000000101665 kg of Acenaphthene to freshwater. Multiplying by the bottle's treatment scaling factor gives 6.608225 × 10−14 kg. Because the migrated archive retains additional decimal digits in its emission coefficient, the native calculation reports a treatment-process contribution of approximately 6.608199 × 10−14 kg. The two values agree within the precision shown in the tutorial figure; this check verifies only that single process's contribution to that freshwater emission flow.[32]

Other processes in the background system also emit that same freshwater Acenaphthene flow. Including their contributions brings the system-wide inventory total for that flow to approximately 1.789707 × 10−13 kg. That system total and the scaled treatment contribution above answer questions of different scope. Any numerical comparison must identify the exact process, flow, emission compartment, and aggregation scope so that two differently scoped numbers are not mistaken for contradictory outputs from the same run.[33]

Carbon dioxide (CO₂) extends this distinction from inventory to impact indicator. For the selected CO₂ emission-to-air flow, the treatment process contributes approximately 0.157428377 kg, while the system-wide inventory total for that same flow is approximately 0.336530863 kg. Although the archived CML GWP100a method assigns that flow a characterization factor of 1 kg CO₂ eq per kg emitted, other characterized greenhouse gases also enter the category, bringing the category total to 0.369674399 kg CO₂ eq. Even when a characterization factor equals 1, a process contribution, a single-flow inventory total, and a category total remain three distinct quantities.[34]

Once process contributions, inventory totals, and category totals are separated, vary only the allocation setting. Under the archived project's economic allocation, the material-flow-logic model yields a GWP100a score of approximately 0.265341691 kg CO₂ eq, compared with approximately 0.369674399 kg CO₂ eq without allocation; both match the values stored in the archived report within verification tolerance. The treatment scaling factor itself does not change—only the share of burden assigned to the reference function changes. A lower score therefore does not prove that less waste was treated or that co-produced electricity and steam displaced other activities in reality.[35]

Screenshots printed in the tutorial support only a narrower check of displayed digits. The tutorial pane displays GWP100a as 0.36967 kg CO₂ eq and acidification as 0.00100 kg SO₂ eq (kilograms of sulfur dioxide equivalent), matching the modern unallocated calculation to the displayed precision. However, the figure caption reads "Production" while the pane title reads "Usage", the screenshot omits the full target and allocation settings, and a second allocation-project figure carries a different project identity from the archived project. Agreement at displayed rounding precision does not justify merging those materials into a single historical run.[36]

If the treatment link is actually severed while the default provider remains populated, does the solver recover the treatment process? In a copy of the same bottle model, deleting only the single saved link from use to treatment—while keeping the waste exchange and its default provider intact and without re-linking—causes the treatment process to disappear from the solved activity index, leaving 0.065 kg of waste stranded at the unlinked boundary. The result table still lists that 0.065 kg with type WASTE_FLOW; it is an open technical flow, and its appearance in the inventory table does not turn it into an elementary flow emitted directly to nature.[37]

No treatment activity was solved in that run. Removing the link lowers GWP100a to approximately 0.212105058 kg CO₂ eq, and at the inventory level the treatment process's freshwater Acenaphthene and CO₂ contributions drop out. Both the category total and the process-level inventory change for a single, explicit modeling reason: the treatment activity is absent. The retained default provider name did not restore the activity; reading only the headline score could mistake an omitted burden for a genuine improvement in waste treatment.[38]

While the bottle example shows whether a link triggers treatment, the Joint Research Centre (JRC) extended International Reference Life Cycle Data System (eILCD) software development kit (SDK) injection-molding example tests process instances and parameters as well. The source model explicitly defines 5 parts at 0.2 kg each, totaling 1 kg. Its metadata restrict it to non-commercial import/export interface testing and exclude real life cycle assessment (LCA) studies, making it suitable for testing how model relationships transfer rather than serving as empirical data for the injection-molding industry.[39]

The seven process instances in the source model reference six distinct process universally unique identifiers (UUIDs): two electricity instances point to the same grid data set, one serving rail transport and the other serving injection molding and washing. In the source file, those two instances carry their own connections, groupings, and scaling factors. Ordinary import merges both electricity demands onto a single provider. The source model preserves the distinction between the two instances, whereas the imported calculation graph uses one shared coordinate; whether other UUID-sharing instances can be merged equivalently depends on their individual roles and connections.[40]

Four connections also bridge mismatched flow objects across their two ends, using different flow UUIDs such as cargo before and after transport or the required plastic granulate. The ordinary openLCA importer inserts a connector process for each of those four links, recording a quantity of 1 in each end's reference unit: three kg-to-kg bridges and one MJ-to-MJ electricity bridge. Import warnings flag these bridges and cannot be dropped from interpretation, nor can a 1:1 bridge here be generalized to arbitrary same-named flows, different units, or materials of differing mass.[41]

After import, the product system target reads simply 1 kg; knowing how many parts that represents requires knowing the mass per part. The saved Baseline parameter set stores override values for part mass, rail distance, and rail utilization, while the reference output still uses a formula evaluated from part mass. Explicitly applying that parameter set divides the 1 kg target by 0.2 kg per reference activity, yielding 5 model activity units. The system target alone cannot supply that multiplier—it is recomputed from the formula, and whether the source instances' groupings and scaling factors transferred verbatim still requires separate verification.[42]

A controlled test isolates the effect of part mass. Changing the mass per part to 1 kg while keeping the delivered target at 1 kg and retaining the rail parameter overrides reduces the required molding activity to 1 unit. Because the source electricity formula contains a fixed term that does not scale proportionally with part mass, delivering the same total mass of plastic no longer requires the same electricity. In this author-controlled comparison, fossil CO₂ inventory drops by approximately 0.064471482 kg relative to the five-part case; this exposes the piece-count effect built into the formula rather than measuring emissions from a real factory changing product designs.[43]

One must also check whether the solver actually loads the saved parameters. In this version of openLCA, CalculationSetup.of reads the product system's target amount but does not automatically apply parameter sets saved in the system. The runs above pass Baseline explicitly; omitting all parameter overrides alters the rail parameters as well, confounding the comparison with a second change. Isolating the effect of part mass requires holding all other parameters at their original values.[44]

Tracing the end-of-life injection-molding machine along its source connection reveals who actually demands activity from whom. The source example classifies the end-of-life machine as a Product flow: the molding process outputs it, and the end-of-life treatment process takes it as a positive input serving as the treatment reference. Ordinary import preserves the Product flow type and treats the product-output side as the provider. As imported, the link therefore means "end-of-life treatment draws the discarded machine from injection molding". Starting from the demanded molded parts, injection molding does not pull downstream treatment across that product-supply edge. Even when a link resolves cleanly, the actual direction of demand must be read from provider and recipient roles.[45]

In the solved activity index, an extra molding coordinate appears with the end-of-life machine as output, yet no activity coordinate exists for end-of-life treatment. Approximately 4.000000 × 10−6 kg of end-of-life machine remains in the open inventory as a PRODUCT_FLOW. The solver computes activities for the graph it receives, while the omitted end-of-life treatment stays outside the result.[46]

Two gas inventories confirm the missing treatment. The source model's designated resulting process reports 1.8919649886152838 kg of fossil CO₂ in its resultingAmount field, whereas the imported graph yields approximately 1.891961100 kg; subtracting the unrounded values retained by the program—rather than the rounded display values shown here—leaves a shortfall of approximately 3.888308 × 10−6 kg. Multiplying the unlinked end-of-life machine mass by the source treatment coefficient of 0.972076908272198 kg CO₂/kg gives approximately 3.888308 × 10−6 kg, and the shortfall in fossil carbon monoxide (CO) likewise matches that treatment contribution. Explaining the shortfall does not insert treatment into the imported graph; the native output still lacks that contribution and does not fully reproduce the source file's two gas totals.[47]

Checking only quantities unaffected by end-of-life treatment can hide this omission. Primary energy from hydropower, for instance, computes to approximately 62.286789763 MJ in the native run—matching the source file's designated result—simply because the omitted machine-treatment process has no hydropower input. Auditing only that resource flow, or rounding CO₂ to two decimal places, would mask the discrepancy in both gas inventories. Verifying whether key processes entered the calculation requires selecting quantities sensitive to those processes.[48]

After checking those two gases, inspect what the source file's designated result actually lists. Under the source relations, washing generates approximately 0.019400 kg of unlinked plastic waste, which the native inventory preserves, whereas the seven exchanges of the designated resulting process omit it. Moreover, all six non-reference exchanges in that resulting file report differing meanAmount and resultingAmount values despite having no variable reference, whereas ILCD documentation specifies that resultingAmount equals meanAmount multiplied by the referenced variable and should equal meanAmount when no variable is referenced. The comparison here uses the source file's recorded resultingAmount and leaves that discrepancy visible; one cannot treat a file as a benchmark while silently patching or completing it.[49]

The same example also surfaces a separate versioning issue. The source electricity flow requests flow property version 28.00.000, whereas the file resolved at its Uniform Resource Identifier (URI) carries version 03.00.000. Matching UUIDs allow the importer to locate a usable record, but verifying whether the requested version was actually satisfied requires checking the version metadata directly—an identical energy total cannot answer that question.[50]

8.3 Model Conversion and Reference Levels

Why must model conversions still check the system target? Because "reference" operates at several distinct levels. The functional unit defines the required performance; the reference flow translates that requirement into the output quantity of a specific process. A data set's quantitative reference states the basis quantity of that record, and ILCD Format 1.1 also permits functional units, other parameters, or production periods as reference types. A flow data set's reference flow property specifies the default physical quantity—such as mass or energy—used to measure the flow. Although these levels connect, the numeric value of a single reference exchange cannot automatically stand in for the full quantity and performance required by a study.[51]

Rescaling an accounting basis must also be separated from changing the study's external demand. In a fixed linear model As = f and g = Bs, s is the vector of process scaling factors, f is the external demand vector, and g is the environmental inventory. Rescaling every process column's technical and environmental coefficients to a new basis via an invertible positive diagonal matrix D gives A′ = AD and B′ = BD; under the same demand f, the new scaling vector is s′ = D⁻¹s, and the inventory remains B′s′ = Bs. Activity multipliers change, while the inventory does not. That invariance requires checking the entire column alongside the demand vector; dropping the independent target and substituting one record's reference basis as the new demand changes how much the model is being asked to deliver.[52]

Knowing which activities belong to the original graph raises the next question: after exporting a model and importing it back, does the system still deliver the originally requested quantity? Answering requires stating the format, reader/writer implementation, and calculation setup. Both round-trips of the bottle model use the same openLCA version: JavaScript Object Notation for Linked Data (JSON-LD) exports the product system, its dependencies, and the original CML method, whereas eILCD exports the product system and dependencies while retaining openLCA extensions written by the exporter. Because the CML method was not selected for the eILCD export, the eILCD round-trip compares only inventories and does not test whether eILCD preserves impact-method data.[53]

The openLCA 2 manual notes that material flow logic for waste modeling was introduced in openLCA 1.7, whereas earlier releases used the opposite direction approach. That milestone dates the convention's introduction as recounted in the manual; determining how a legacy database migrates and solves in a given release still requires checking that migration's logs and calculation behavior.[54]

Start by testing both round-trips with the original 0.065 kg system target. Both paths preserve the inspected process identities, versions, units, and all 9 saved links, and signed inventories match under their respective targets; JSON-LD also reproduces the compared CML category results. Because the 0.065 kg system target happens to equal the reference exchange amount here, this first test cannot yet reveal whether a format carries an independently set system target.[55]

A second round-trip separates the two by doubling the system target to 0.13 kg while leaving the process quantitative reference at 0.065 kg. The source model now demands twice the activity. Re-importing via JSON-LD restores the 0.13 kg target, whereas this eILCD export path writes no independent system target, causing the importer to fall back to the reference exchange's 0.065 kg. The eILCD-imported model still solves without error, yet its recovered demand is only half of what was originally requested.[56]

The inventory of the selected CO₂ flow scales directly with the recovered target. Preserving the doubled target in JSON-LD yields approximately 0.673061727 kg, whereas re-importing through eILCD yields approximately 0.336530863 kg. Process coefficients and saved links survived intact; the smaller recovered target reduced the activity level. That ratio documents the behavior of the specific export and import paths tested.[57]

A separate check distinguishes stored signs from interface display direction. In the background database, the same "municipal waste" flow appears both as a positive input and as a negative output. In this non-regionalized index—which does not split rows by location—both entries collapse into a single row that retains the input flag of whichever exchange is registered first, and the result view uses that input/output flag to flip display signs. Different re-import runs exhibited different summary flags even while inspected process exchange fields, signed coefficients, and inventory quantities remained identical. Because this behavior occurred in both JSON-LD and eILCD and no single root cause was traced here, it cannot be attributed solely to doubling the target or to one file format.[58]

Published tool-comparison studies likewise require checking what objects were actually converted. Savioli and colleagues' evaluation of Lavoisier compares EcoSpold 2 and ILCD process data sets while explicitly excluding the eILCD life cycle models examined here. Their study documents provider-field loss and notes that a proper life cycle impact assessment (LCIA) result comparison could not be completed. Such studies show which field changes occur in the tested tools and data sets, whereas verifying activity equivalence in the bottle and injection-molding cases requires inspecting those models and their calculated results directly.[59]

8.4 Inventory Characterization and Zero Values

Having a flow quantity in the inventory does not yet establish how it enters an impact indicator. In openLCA's characterization-factor editor, each record pairs a flow with a factor value, a unit, and a location. All four fields must be verified to know which inventory entry a given number multiplies.[60]

Calculating an impact category first matches inventory flows to applicable characterization factors and then multiplies them. Even in a non-regionalized setup, matching requires verifying flow identity, unit and property conversions, and geographic applicability—a factor valid only for one location cannot be applied globally by default. The method, version, and category define what is being assessed, while actual factor matching determines which flows enter the sum.[61]

When a flow contributes nothing to an impact score, work back from the total to coverage checks. The openLCA manual notes that LCIA Checks list flows not evaluated in a given category, with mapping mismatches being only one possible cause. Once an uncharacterized flow is flagged, one must still determine whether a valid factor exists and applies before explaining why the flow was excluded from the indicator.[62]

8.4.1 Which Side Models Environmental Transport

The division of labor between inventory and characterization also explains part of the boundary divergence in agriculture. The English corrigendum republication of European Union (EU) Commission Recommendation (EU) 2021/2279 provides an expert-judgment default split for applied pesticide active ingredients—90% to agricultural soil, 9% to air, and 1% to water—while permitting more specific data when available. The recommendation notes that its USEtox model simulates environmental fate starting from each receiving compartment. By contrast, the ILCD 2010 Handbook generally estimates specific emission pathways leaving managed land. Because one starts by partitioning the applied dose and the other starts from defined field-level emissions, two columns both labeled "kg pesticide" cannot be placed side by side as equivalent.[63]

If an applied active-ingredient dose is q, applying those default fractions with compatible linear characterization factors yields an indicator score of q × (0.90 c(soil) + 0.09 c(air) + 0.01 c(water)), where the three c terms represent factors starting from soil, air, and water respectively. Another model that already estimates compartment-specific emissions must multiply those emissions by factors compatible with its own interface. Interpreting equal scores as model correspondence requires checking emission quantities, starting compartments, and which environmental transport processes are included; a single weighted sum can also coincide accidentally when factors happen to be equal or opposing differences cancel out. Equal applied doses do not establish correspondence, and transport already embedded in a characterization factor cannot be added a second time without verification.[64]

Nor can this division of labor be reduced to "EF always treats applied amounts as emissions". For phosphorus eutrophication, the same recommendation prescribes using water emissions with water-compartment factors when runoff data are available, and allows using applied amounts paired with soil factors that incorporate runoff only when runoff data are lacking. The difference lies in whether transport is estimated in the inventory or absorbed into the characterization factor. Interface choices must therefore be read together with the impact model: defaults cannot be passed off as field measurements, and splitting more processes in the inventory does not by itself guarantee higher accuracy.[65]

8.4.2 What Remains to Verify After Seeing a Zero

Suppose an inventory contains 3 kg of a given flow. If an applicable characterization factor has been found and confirmed to be zero, the contribution is 3 × 0 = 0. If no applicable factor is known, that flow's contribution remains unknown, and summing the remaining flows produces only a partial total. This arithmetic example clarifies the difference between those two information states; how large the unknown contribution is, or whether it could alter a comparison ranking, requires empirical evidence.[66]

Even locating a factor record with a numeric value of zero does not yet explain what that zero means. ILCD Format 1.1 documentation for the meanValue field recommends that when an elementary flow is known to contribute to an impact topic yet the method provides no factor, the data set should still reference that flow with a value of zero. Such a zero preserves an unresolved missing-factor state. It uses the exact same field and numeral as an evidence-backed zero factor while carrying a completely different meaning.[67]

Real data packages demand one more layer of inspection. In EF 3.1, the inspected freshwater ecotoxicity entry for "aluminium (iii)" to long-term unspecified water carries a zero value, yet its Extensible Markup Language (XML) comment gives no rationale; from that XML alone, one cannot tell whether the zero is a placeholder or reflects an absence of ecological effect. By contrast, the EF 3.1 update report explicitly explains setting certain entries—such as sulfur freshwater ecotoxicity—to zero; that documents the method authors' decision, though it still does not prove zero real-world effect under every conceivable condition. A recorded value, a methodological rationale, and a real-world effect each require their own evidence.[68]

The diagnostic below operates on the system-wide inventory of the air CO₂ flow in the fixed bottle model rather than on the incineration process's emission alone. Its purpose is solely to test whether a factor record is picked up by the solver; pairing that inventory with an artificial coefficient does not create an alternative environmental impact assessment of the bottle.[69]

The same bottle calculation graph supports a controlled probe of when a factor enters multiplication. Keeping the full inventory intact in openLCA 2.7.0, an artificial single-category diagnostic method with no environmental interpretation is attached to the air CO₂ flow. Setting the author-defined factor to 2 multiplies the approximately 0.336530863 kg inventory to yield 0.673061727 diagnostic units. This positive control confirms that the record is matched and multiplied; the factor 2 itself represents no environmental impact.[70]

Having confirmed that a non-zero factor enters the calculation, keep the same category and first change the factor to 0—leaving one zero-valued factor record in the database—and then delete that factor so zero records remain. The inventory is unchanged, yet both native runs produce 0 in the corresponding characterization-matrix cell and 0 for the diagnostic score. At the numeric output layer, the two source states become indistinguishable; telling them apart requires returning to the stored factor records and matching metadata.[71]

The archived CML method itself leaves real inventory flows uncharacterized. Freshwater Acenaphthene—the flow used earlier to verify the treatment process's inventory—has no factor record with a matching UUID in that method. Although the inventory records emissions of that substance, the calculation found no matching characterization record for the flow, so its environmental effect cannot be judged to be zero.[72]

Reports should allow readers to trace why any flow did not contribute to an indicator. Distinguishing "matched with factor equal to zero", "no applicable factor found", "explicitly not applicable", and "proxy factor applied"—alongside the rationale for each—gives readers the minimum transparency needed. Specific status codes may vary, but readers must be able to separate evaluated flows, unknown flows, and proxy-supported judgments.[73]

Whenever an impact contribution reads zero, trace three steps in order: whether the relevant environmental flow is present in the inventory, whether the selected method matched a factor to it, and what value and rationale that matched record carries. A missing record may reflect category inapplicability rather than an important omission, while a zero record requires separating an evidence-backed zero, a documented placeholder, and an unexplained zero. The bottle probe above tested only two author actions—setting a factor to zero and deleting the row—showing that numeric outputs can coincide without explaining why any real method assigns zero. Likewise, the open waste flow and category totals reported in the unlinked-bottle test do not by themselves establish whether that waste flow was characterized; determining that requires the flow's matching record or item-level contribution.[74]

Alongside category totals, studies should document the method and version, each inventory flow and its location, the matched factor, and the basis for every coverage judgment. Whenever a flow is judged inapplicable or assigned a proxy value, the rationale should be stated explicitly. Neither a similar flow name nor the absence of a region-specific factor is by itself sufficient grounds to substitute another factor. Once software outputs a zero, readers still need these records to interpret what that zero means.[75]

In the bottle model, holding reference, links, and allocation constant produced identical activities across two waste encodings. The injection-molding case showed that even when links survive import, calculation can still omit end-of-life treatment. The format round-trips showed that even when all process data remain intact, the recovered system target can shift to a different quantity. Claiming that a model was "preserved" across conversion therefore requires specifying exactly what was verified: flow objects, versions, units, parameters, links, target demand, and characterization mappings.[76]

Once the mechanics of how records enter the solver are clear, the analysis must return to the service being evaluated. Is this material stream actually suitable for that treatment process? Do the manufactured parts and their performance deliver equivalent use? What comparisons can the chosen background data, allocation rules, and impact methods legitimately support? Running a solver reveals what existing records do inside the calculation; determining whether activities are missing or why an inventory flow went uncharacterized requires separate evidence.[77]

Taken together, these checks give "the same model" a concrete operational meaning. Flow objects and environmental interfaces must correspond; the activities actually demanded across process links must correspond; accounting bases and external demands must correspond; and inventory flows must match the starting compartments of characterization factors. When those correspondences hold, changing signs or rescaling accounting bases leaves the inventory invariant; when an interface shifts, a treatment link drops, or a target demand is lost, the model is answering a different question. A coinciding headline score never substitutes for verifying those correspondences—which is also why expanding a process network still requires asking what upstream supplies and downstream disposals remain unlinked, rather than mistaking an algebraically balanced graph for complete coverage.[78]

Sources and validity conditions for each judgment are documented in Claims & Evidence Directory. To reproduce both models, consult the material scope and software versions listed in the original-file and native-module reproduction guide.

Notes

  1. Synthesis. Bounded synthesis of boundary provisions read in ISO 2006, CML 2001, and ILCD 2010

    Caveats: The factory-gate example illustrates the two types of boundaries and does not represent an empirical emissions survey of any real facility.

    Premises referenced (1)
  2. Synthesis. Definitions and scope clauses listed in the public preview of the ISO 14040/14044:2006 base editions

    Caveats: Only the specified original clauses of the 2006 base editions were inspected; this does not represent a review of the full standards, subsequent amendments, or current consolidated editions.

    Premises referenced (1)
  3. Synthesis. Comparison of unmanaged disposal in CML 2001 Part 3 §3.2 and ILCD 2010 §§6.6.1 and 7.4.4.2

    Caveats: Unmanaged disposal rules are not generalized to all controlled landfills; both guides specify finer conditions and exceptions.

    Premises referenced (1)
  4. Synthesis. Object differences and conditional consequences across the two inspected guides

    Caveats: No field observations were used to validate the numerical accuracy of either modeling interface for a given site.

    Premises referenced (1)
  5. Synthesis. Comparison of the CML 2001 natural-soil boundary and the ILCD 2010 managed-land boundary

    Caveats: Agricultural provisions retain conditions on baselines, crop or land functions, and persistent substances; no empirical field emission factors are provided here.

    Premises referenced (1)
  6. Interpretation. Specified agricultural, waste, and aggregate-indicator exceptions in ILCD 2010

    Caveats: This explains only the rules and exceptions in the cited historical guidance and does not claim to cover every class of environmental intervention.

    Premises referenced (1)
  7. Source statement. Original Flow and Process data set fields in ILCD Format 1.1

    Caveats: Format field capabilities do not prove how actual software preserves links, resolves versions, or executes calculations.

  8. Source statement. Flow data objects in the openLCA 2 manual

    • Flows (openLCA 2 manual; mutable web edition) — Flows: three flow types; paragraphs following table

    Caveats: This cannot be treated as a mutually exclusive classification shared by all LCA standards.

  9. Source statement. Process editor in openLCA 2

    • Inputs/Outputs (openLCA 2 manual; mutable web edition) — Inputs/Outputs: Flow; Amount; Unit
  10. Interpretation. Analytical distinction between flows and process inputs/outputs in openLCA

    • Flows (openLCA 2 manual; mutable web edition) — Flows: three flow types; paragraphs following table
    • Inputs/Outputs (openLCA 2 manual; mutable web edition) — Inputs/Outputs: Flow; Amount; Unit

    Caveats: This is an analytical distinction and is not claimed to be a uniform terminological definition adopted by all standards.

    Premises referenced (2)
  11. Synthesis. Comparison of normative terminology with ILCD Format 1.1 and openLCA 2 data-representation layers

    Caveats: No cross-software conversion experiment was performed for ILCD Other flow records.

    Premises referenced (2)
  12. Synthesis. Selected official EF 3.1 flows, mass property and unit definitions, and freshwater ecotoxicity method entries

    • EF 3.1 reference package — selected flows and methods (July 2022 reference release; official package retrieved 2026-11-14) — ILCD/flows/1c54ac00-a958-487b-918b-b25d6100aa7a.xml, flowInformation/quantitativeReference, administrativeInformation/publicationAndOwnership/common:dataSetVersion, flowProperties
    • EF 3.1 reference package — selected flows and methods (July 2022 reference release; official package retrieved 2026-11-14) — ILCD/flows/5311ad70-32a6-4a2f-8f1b-50501dba37fc.xml, flowInformation/quantitativeReference, administrativeInformation/publicationAndOwnership/common:dataSetVersion, flowProperties
    • EF 3.1 reference package — selected flows and methods (July 2022 reference release; official package retrieved 2026-11-14) — ILCD/lciamethods/05316e7a-b254-4bea-9cf0-6bf33eb5c630.xml, lines 29–31, 87, 322648–322657, 618328–618337, 635218–635227
    • EF 3.1 reference package — selected flows and methods (July 2022 reference release; official package retrieved 2026-11-14) — EF-v3.1 (4)/ILCD/flowproperties/93a60a56-a3c8-11da-a746-0800200b9a66.xml: quantitativeReference and referenced dataset/unit IDs (mass flow property linked to unit group and internal ID 0, kg)
    • EF 3.1 reference package — selected flows and methods (July 2022 reference release; official package retrieved 2026-11-14) — EF-v3.1 (4)/ILCD/unitgroups/93a60a57-a4c8-11da-a746-0800200c9a66.xml: quantitativeReference and referenced dataset/unit IDs (mass flow property linked to unit group and internal ID 0, kg)
    • EF 3.1 reference package — selected flows and methods (July 2022 reference release; official package retrieved 2026-11-14) — EF-v3.1 (4)/ILCD/flows/fe0acd60-3ddc-11dd-a72c-0050c2490048.xml: dataSetInformation/name and elementaryFlowCategorization, and matching UUID entry in LCIA method 05316e7a

    Caveats: Only selected members of the official package were inspected; full mappings, underlying factor-calculation routines, and environmental effects were not verified. The reason for the zero entry in long-term water remains undetermined.

    Premises referenced (1)
  13. Synthesis. Bounded comparison of ISO 2006 definitions, CML 2001 terminology, and native software type observations

    Caveats: This does not determine the legal waste classification of any specific material and does not treat historical economic-value classifications as a universal rule across all databases.

    Premises referenced (2)
  14. Synthesis. Conditional correspondence between Suh (2004, dissertation Chapter III) and ILCD 2010 treatment-direction rules

    Caveats: Services measured in the same physical unit do not guarantee identical composition, facility, or environmental consequences; a handbook's service representation does not automatically equal openLCA's negative-product encoding.

    Premises referenced (1)
  15. Synthesis. How an exchange demands another activity; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (1)
  16. Interpretation. How an exchange demands another activity; named cases using pinned source files and openLCA 2.7.0 native modules

  17. Source statement. Material flow logic as described in the openLCA 2 manual

    • Waste modelling (openLCA 2 manual; describes transition at 1.7) — Material flow logic; Creating a waste treatment process
  18. Calculation. How an exchange demands another activity; named cases using pinned source files and openLCA 2.7.0 native modules

    • openLCA Tutorial: Basic Modelling in openLCA (Manual v1.3, June 2020, for openLCA 1.10; 51 pages) — Title page and Section 1, p. 6 (software, background database, LCIA method package, and database backup link)
    • Master_bottles_solved_20200319.zolca (GreenDelta tutorial companion Derby backup; internal ZIP dates 2020-03-20 to 2020-03-24, re-hosted February 2025; upgrade log includes schema v8) — ZIP directory, service.properties, and _olca_/updates/5912d392-e353-4158-a730-e3df6e7cfb5b.MF; seg0/c830.dat, uncompressed byte offsets 33526, 33842, 34491, and 34806 (four product system names); seg0/c740.dat, byte offsets 262262, 262448, 263703, and 263912 (use and treatment process names); seg0/c890.dat (adjacent LCIA method name markers)
    • openLCA modules 2.7.0 — pinned release source — CalculationSetup.java (Version 2.7.0, tag corresponding to commit 0cee8c739a6f98642761fb72e25bbcfb11f90be2) — org/openlca/core/model/CalculationSetup.java, lines 22–54, 115–173, 180–218, and 239–275 (context)

    Caveats: This case uses JavaSolver and pinned dependencies; the original database and full re-exports are not redistributed with the public summary.

    Premises referenced (2)

    Download calculation input (v1.0.0)

  19. Interpretation. How an exchange demands another activity; named cases using pinned source files and openLCA 2.7.0 native modules

  20. Source statement. Two encodings of the same treatment quantity; named cases using pinned source files and openLCA 2.7.0 native modules

  21. Source statement. Opposite direction approach as described in the openLCA 2 manual

    • Waste modelling (openLCA 2 manual; describes transition at 1.7) — Opposite direction approach; numbered steps 1–2
  22. Interpretation. Two encodings of the same treatment quantity; named cases using pinned source files and openLCA 2.7.0 native modules

  23. Calculation. Two encodings of the same treatment quantity; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (4)
  24. Calculation. Two encodings of the same treatment quantity; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (1)
  25. Synthesis. Reading and comparing the two waste-modeling conventions above

    • Waste modelling (openLCA 2 manual; describes transition at 1.7) — Material flow logic; Creating a waste treatment process
    • Waste modelling (openLCA 2 manual; describes transition at 1.7) — Opposite direction approach; numbered steps 1–2

    Caveats: The existence of two modeling conventions does not prove that any two models can be converted losslessly into one another.

    Premises referenced (2)
  26. Source statement. Technosphere matrix conventions in Brightway latest documentation

    • Matrix Construction (Brightway latest documentation; initial access 2026-11-03; selected HTML carrier acquired 2026-11-08) — Positive and Negative Values in the technosphere
    • Matrix Construction (Brightway latest documentation; initial access 2026-11-03; selected HTML carrier acquired 2026-11-08) — Matrix Construction introduction; What Data Enters the technosphere Matrix? Important box
  27. Source statement. Important callout box in Brightway latest Matrix Construction documentation

    • Matrix Construction (Brightway latest documentation; initial access 2026-11-03; selected HTML carrier acquired 2026-11-08) — Matrix Construction introduction; What Data Enters the technosphere Matrix? Important box

    Caveats: This reflects the conventions stated in the cited documentation; the behavior of any specific installed version must be verified against that version.

  28. Calculation. Two encodings of the same treatment quantity; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (2)
  29. Calculation. Two encodings of the same treatment quantity; named cases using pinned source files and openLCA 2.7.0 native modules

    Caveats: Pairing is explicitly restricted to these two named models; minor floating-point summation-order differences occur in inventory and category totals, and byte-for-byte output identity is not claimed.

    Premises referenced (4)
  30. Calculation. Author's algebraic derivation on the fixed bottle reference quantities, distinct from native software runs

    Caveats: No new software run was executed here; negating a balance row for a service direction is a different argument from two native field encodings assembling into the same matrix.

    Premises referenced (3)
  31. Calculation. Process contribution, single-flow total, and category total; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (2)
  32. Calculation. Process contribution, single-flow total, and category total; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (1)
  33. Calculation. Process contribution, single-flow total, and category total; named cases using pinned source files and openLCA 2.7.0 native modules

    • Master_bottles_solved_20200319.zolca (GreenDelta tutorial companion Derby backup; internal ZIP dates 2020-03-20 to 2020-03-24, re-hosted February 2025; upgrade log includes schema v8) — ZIP directory, service.properties, and _olca_/updates/5912d392-e353-4158-a730-e3df6e7cfb5b.MF; seg0/c830.dat, uncompressed byte offsets 33526, 33842, 34491, and 34806 (four product system names); seg0/c740.dat, byte offsets 262262, 262448, 263703, and 263912 (use and treatment process names); seg0/c890.dat (adjacent LCIA method name markers)
    • openLCA modules 2.7.0 — pinned release source — ImpactBuilder.java (Version 2.7.0, tag corresponding to commit 0cee8c739a6f98642761fb72e25bbcfb11f90be2) — org/openlca/core/matrix/ImpactBuilder.java, lines 99–119, 123–174, 181–214, and 226–251 (context)
    • openLCA modules 2.7.0 — pinned release source — ResultProvider.java (Version 2.7.0, tag corresponding to commit 0cee8c739a6f98642761fb72e25bbcfb11f90be2) — org/openlca/core/results/providers/ResultProvider.java, lines 585–597 (context)
    Premises referenced (2)
  34. Calculation. Process contribution, single-flow total, and category total; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (2)
  35. Interpretation. Process contribution, single-flow total, and category total; named cases using pinned source files and openLCA 2.7.0 native modules

  36. Interpretation. One kilogram does not specify how many parts; named cases using pinned source files and openLCA 2.7.0 native modules

    • eILCD SDK v2.1.1 — example archive (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — SDK ZIP central directory, eILCD-SDK_v2.1.1/CHANGES.txt, and ILCD/processes, ILCD/lifecyclemodels, and ILCD/flows directories
    • eILCD SDK v2.1.1 — LDPE example life cycle model XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/lifecyclemodels/10062015cc-184a-41b8-8fa6-49e999cbd101.xml: /lifeCycleModelDataSet/lifeCycleModelInformation/dataSetInformation, quantitativeReference, and technology/processes/processInstance[@dataSetInternalID=2]
    • eILCD SDK v2.1.1 — LDPE example life cycle model XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/lifecyclemodels/10062015cc-184a-41b8-8fa6-49e999cbd101.xml: modellingAndValidation/dataSourcesTreatmentEtc, complianceDeclarations, and administrativeInformation/publicationAndOwnership (qualifies)
  37. Calculation. One kilogram does not specify how many parts; named cases using pinned source files and openLCA 2.7.0 native modules

    • eILCD SDK v2.1.1 — LDPE example life cycle model XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/lifecyclemodels/10062015cc-184a-41b8-8fa6-49e999cbd101.xml: technology/processes (instances #0–6), connections/outputExchange/downstreamProcess, and groups
    • eILCD SDK v2.1.1 — grid process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/e38740ed-4e9e-4f4c-ae17-251ca7442c58.xml:: reference #509 and exchanges #1, 4, 5, 509
    • openLCA modules 2.7.0 — pinned release source — ModelImport.java (Version 2.7.0, tag corresponding to commit 0cee8c739a6f98642761fb72e25bbcfb11f90be2) — org/openlca/io/ilcd/input/models/ModelImport.java, lines 41–74, 76–154, 160–198, and 208–222 (context)
    Premises referenced (2)
  38. Calculation. One kilogram does not specify how many parts; named cases using pinned source files and openLCA 2.7.0 native modules

    • eILCD SDK v2.1.1 — LDPE example life cycle model XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/lifecyclemodels/10062015cc-184a-41b8-8fa6-49e999cbd101.xml: technology/processes (instances #0–6), connections/outputExchange/downstreamProcess, and groups
    • eILCD SDK v2.1.1 — rail process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/24b22ed7-6187-4bea-b8b1-eccbfc267cb9.xml :: reference #2, operation location, mathematicalRelations and exchanges #0–2
    • eILCD SDK v2.1.1 — granulate process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/8ddfe862-e580-47ab-a248-b62c6f4323d4.xml:: reference #239, operation location and exchanges #1, 4, 5, 239
    • openLCA modules 2.7.0 — pinned release source — ModelImport.java (Version 2.7.0, tag corresponding to commit 0cee8c739a6f98642761fb72e25bbcfb11f90be2) — org/openlca/io/ilcd/input/models/ModelImport.java, lines 41–74, 76–154, 160–198, and 208–222 (context)
    Premises referenced (1)
  39. Calculation. One kilogram does not specify how many parts; named cases using pinned source files and openLCA 2.7.0 native modules

    • eILCD SDK v2.1.1 — LDPE example life cycle model XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/lifecyclemodels/10062015cc-184a-41b8-8fa6-49e999cbd101.xml: /lifeCycleModelDataSet/lifeCycleModelInformation/dataSetInformation, quantitativeReference, and technology/processes/processInstance[@dataSetInternalID=2]
    • eILCD SDK v2.1.1 — moulding process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/ecf3ceb8-1907-482e-8550-efd5c1f970e9.xml:: mathematicalRelations and exchanges #0–3, 5–6
    • eILCD SDK v2.1.1 — rail process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/24b22ed7-6187-4bea-b8b1-eccbfc267cb9.xml :: reference #2, operation location, mathematicalRelations and exchanges #0–2
    • openLCA modules 2.7.0 — pinned release source — CalculationSetup.java (Version 2.7.0, tag corresponding to commit 0cee8c739a6f98642761fb72e25bbcfb11f90be2) — org/openlca/core/model/CalculationSetup.java, lines 22–54, 115–173, 180–218, and 239–275 (context)
    • openLCA modules 2.7.0 — pinned release source — ModelImport.java (Version 2.7.0, tag corresponding to commit 0cee8c739a6f98642761fb72e25bbcfb11f90be2) — org/openlca/io/ilcd/input/models/ModelImport.java, lines 41–74, 76–154, 160–198, and 208–222 (context)
    Premises referenced (2)
  40. Calculation. One kilogram does not specify how many parts; named cases using pinned source files and openLCA 2.7.0 native modules

    • eILCD SDK v2.1.1 — moulding process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/ecf3ceb8-1907-482e-8550-efd5c1f970e9.xml:: mathematicalRelations and exchanges #0–3, 5–6
    • eILCD SDK v2.1.1 — grid process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/e38740ed-4e9e-4f4c-ae17-251ca7442c58.xml:: reference #509 and exchanges #1, 4, 5, 509
    • openLCA modules 2.7.0 — pinned release source — CalculationSetup.java (Version 2.7.0, tag corresponding to commit 0cee8c739a6f98642761fb72e25bbcfb11f90be2) — org/openlca/core/model/CalculationSetup.java, lines 22–54, 115–173, 180–218, and 239–275 (context)
    Premises referenced (1)
  41. Interpretation. One kilogram does not specify how many parts; named cases using pinned source files and openLCA 2.7.0 native modules

    • openLCA modules 2.7.0 — pinned release source — CalculationSetup.java (Version 2.7.0, tag corresponding to commit 0cee8c739a6f98642761fb72e25bbcfb11f90be2) — org/openlca/core/model/CalculationSetup.java, lines 22–54, 115–173, 180–218, and 239–275
    • eILCD SDK v2.1.1 — LDPE example life cycle model XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/lifecyclemodels/10062015cc-184a-41b8-8fa6-49e999cbd101.xml: /lifeCycleModelDataSet/lifeCycleModelInformation/dataSetInformation, quantitativeReference, and technology/processes/processInstance[@dataSetInternalID=2]
    • eILCD SDK v2.1.1 — rail process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/24b22ed7-6187-4bea-b8b1-eccbfc267cb9.xml :: reference #2, operation location, mathematicalRelations and exchanges #0–2
  42. Calculation. Treatment can still be omitted even when links are preserved; named cases using pinned source files and openLCA 2.7.0 native modules

    • eILCD SDK v2.1.1 — LDPE example life cycle model XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/lifecyclemodels/10062015cc-184a-41b8-8fa6-49e999cbd101.xml: technology/processes (instances #0–6), connections/outputExchange/downstreamProcess, and groups
    • eILCD SDK v2.1.1 — machine process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/e642549a-ed92-4db7-a877-5b53e5acdd8c.xml :: reference #0 and exchanges #0–2
    • eILCD SDK v2.1.1 — EoL plastic injection machine flow XML (eILCD SDK v2.1.1; flow dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/flows/a1ff365a-b063-4993-9ddc-6c68dd45ff81.xml, lines 6–8, 17, 22, 41, and 45–50 (UUID, name, typeOfDataSet, and reference flow property ID 0)
    • eILCD SDK v2.1.1 — moulding process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/ecf3ceb8-1907-482e-8550-efd5c1f970e9.xml:: mathematicalRelations and exchanges #0–3, 5–6
    • openLCA modules 2.7.0 — pinned release source — ModelImport.java (Version 2.7.0, tag corresponding to commit 0cee8c739a6f98642761fb72e25bbcfb11f90be2) — org/openlca/io/ilcd/input/models/ModelImport.java, lines 41–74, 76–154, 160–198, and 208–222 (context)
    Premises referenced (2)
  43. Calculation. Treatment can still be omitted even when links are preserved; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (1)
  44. Calculation. Treatment can still be omitted even when links are preserved; named cases using pinned source files and openLCA 2.7.0 native modules

    • eILCD SDK v2.1.1 — designated resulting process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/a91683fe-3b0b-471c-a007-f9d8b4e29d5a.xml: quantitativeReference, LCIMethodAndAllocation/typeOfDataSet, and exchanges #1, #2, #3, #5, #6, #7, and #10
    • eILCD SDK v2.1.1 — machine process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/e642549a-ed92-4db7-a877-5b53e5acdd8c.xml :: reference #0 and exchanges #0–2
    • eILCD SDK v2.1.1 — moulding process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/ecf3ceb8-1907-482e-8550-efd5c1f970e9.xml:: mathematicalRelations and exchanges #0–3, 5–6
    • openLCA modules 2.7.0 — pinned release source — TechIndex.java (Version 2.7.0, tag corresponding to commit 0cee8c739a6f98642761fb72e25bbcfb11f90be2) — org/openlca/core/matrix/index/TechIndex.java, lines 85–150 (context)
    Premises referenced (1)
  45. Calculation. Treatment can still be omitted even when links are preserved; named cases using pinned source files and openLCA 2.7.0 native modules

    • eILCD SDK v2.1.1 — designated resulting process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/a91683fe-3b0b-471c-a007-f9d8b4e29d5a.xml: quantitativeReference, LCIMethodAndAllocation/typeOfDataSet, and exchanges #1, #2, #3, #5, #6, #7, and #10
    • eILCD SDK v2.1.1 — machine process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/e642549a-ed92-4db7-a877-5b53e5acdd8c.xml :: reference #0 and exchanges #0–2
    • eILCD SDK v2.1.1 — grid process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/e38740ed-4e9e-4f4c-ae17-251ca7442c58.xml:: reference #509 and exchanges #1, 4, 5, 509
    • eILCD SDK v2.1.1 — granulate process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/8ddfe862-e580-47ab-a248-b62c6f4323d4.xml:: reference #239, operation location and exchanges #1, 4, 5, 239
    Premises referenced (1)
  46. Calculation. Treatment can still be omitted even when links are preserved; named cases using pinned source files and openLCA 2.7.0 native modules

    • eILCD SDK v2.1.1 — wash process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/23dd327f-d58e-42da-82ac-351c42df0127.xml :: reference #3, mathematicalRelations and exchanges #1–7
    • eILCD SDK v2.1.1 — designated resulting process XML (eILCD SDK v2.1.1; model dataset version 01.00.000, XML version attribute 1.1) — eILCD-SDK_v2.1.1/ILCD/processes/a91683fe-3b0b-471c-a007-f9d8b4e29d5a.xml: quantitativeReference, LCIMethodAndAllocation/typeOfDataSet, and exchanges #1, #2, #3, #5, #6, #7, and #10
    • ILCD Format 1.1 Documentation — Process data set (ILCD Format 1.1) — Process data set, Quantitative reference; Inputs and Outputs 1-7-32-119/120/123/124/125/126
    Premises referenced (2)
  47. Interpretation. Treatment can still be omitted even when links are preserved; named cases using pinned source files and openLCA 2.7.0 native modules

  48. Synthesis. Reference hierarchy across ISO 14044:2006 §4.2.3.2, ILCD 2010, and ILCD Format 1.1

    Caveats: Conceptual alignment across reference levels does not prove that a given export format carries an independent product-system target.

    Premises referenced (2)
  49. Calculation. Author's basis-transformation derivation within the Heijungs–Suh fixed linear model

    • The Computational Structure of Life Cycle Assessment — author-linked sample (Author public sample chapter from the 2002 book; Springer reprint ISBN 978-90-481-6041-9; eBook ISBN 978-94-015-9900-9; see also 2025-06-07 erratum) — Section 2.1 (pp. 14–15; PDF pp. 26–27) and Section 2.3 (pp. 20–23; PDF pp. 32–35), Eqs. (2.8)–(2.9), Definition 4, and Theorems 1–2 (context)

    Caveats: Validity requires the same proportionally scalable linear model and an invertible positive basis transformation; it does not establish unconditional linearity of real production or general conversion equivalence.

    Premises referenced (1)
  50. Calculation. Which question a file round-trip preserves; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (2)
  51. Source statement. Software version history as recounted in the openLCA 2 manual

    • Waste modelling (openLCA 2 manual; describes transition at 1.7) — Material flow logic opening paragraph; Opposite direction approach opening paragraph

    Caveats: Version history relies on the manual's own account and does not prove that openLCA originated the underlying concept.

  52. Calculation. Which question a file round-trip preserves; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (2)
  53. Calculation. Which question a file round-trip preserves; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (2)
  54. Calculation. Which question a file round-trip preserves; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (1)
  55. Calculation. Which question a file round-trip preserves; named cases using pinned source files and openLCA 2.7.0 native modules

    Caveats: Which exchange was visited first in each run was not traced; source code explains the first-registration rule, but no causal effect of working directory, timestamps, or format on traversal order was measured.

    Premises referenced (2)
  56. Source statement. Which question a file round-trip preserves; named cases using pinned source files and openLCA 2.7.0 native modules

  57. Interpretation. Characterization-factor interface in openLCA 2

  58. Interpretation. The same numeric zero can arise from different records; named cases using pinned source files and openLCA 2.7.0 native modules

  59. Source statement. Completeness check in the openLCA 2 manual

  60. Synthesis. Comparison of agricultural interfaces in PEF (EU) 2021/2279 R(01) Annex I §4.4.1.4 and ILCD 2010

    Caveats: Default fractions are not field measurements, do not represent all EF interventions, and do not determine the value of any specific EF 3.1 factor.

    Premises referenced (1)
  61. Calculation. Author's interface derivation from cited PEF pesticide rules and linear characterization

    Caveats: No real pesticide factors were assigned, no field impacts were estimated, and no product rankings were compared; factors across the two interfaces are not assumed equal.

    Premises referenced (1)
  62. Synthesis. Conditional substitution and methodological judgment in PEF (EU) 2021/2279 R(01) Annex I §4.4.1.5

    Caveats: The conditional substitution for phosphorus does not automatically generalize to all pesticides, nutrients, or environmental pathways.

    Premises referenced (1)
  63. Calculation. Information states and arithmetic of a hypothetical inventory; not an empirical impact result

    Caveats: No real environmental impact was calculated; neither the magnitude nor the direction of the unknown term can be inferred from this example.

    Premises referenced (1)
  64. Source statement. Zero-placeholder recommendation for the LCIA factor meanValue field in ILCD Format 1.1 (eDoc 3-23-100-263)

    Caveats: The inspected text is a format recommendation; the presence of a zero row does not prove that any particular real method used it as a placeholder.

  65. Synthesis. Contrast between selected EF 3.1 zero rows and explicit zero-assignment explanations in JRC130796

    Caveats: The authors' full rationale and calculation routines for setting zeros were not reproduced; the explanation for sulfur is not attributed to the zero entry for long-term water aluminum.

    Premises referenced (1)
  66. Interpretation. Input scope and interpretive purpose of the fixed bottle-model diagnostic

    • Master_bottles_solved_20200319.zolca (GreenDelta tutorial companion Derby backup; internal ZIP dates 2020-03-20 to 2020-03-24, re-hosted February 2025; upgrade log includes schema v8) — ZIP directory, service.properties, and _olca_/updates/5912d392-e353-4158-a730-e3df6e7cfb5b.MF; seg0/c830.dat, uncompressed byte offsets 33526, 33842, 34491, and 34806 (four product system names); seg0/c740.dat, byte offsets 262262, 262448, 263703, and 263912 (use and treatment process names); seg0/c890.dat (adjacent LCIA method name markers)
    • openLCA modules 2.7.0 — pinned release source — ImpactBuilder.java (Version 2.7.0, tag corresponding to commit 0cee8c739a6f98642761fb72e25bbcfb11f90be2) — org/openlca/core/matrix/ImpactBuilder.java, lines 99–119, 123–174, 181–214, and 226–251
    • openLCA modules 2.7.0 — pinned release source — ResultProvider.java (Version 2.7.0, tag corresponding to commit 0cee8c739a6f98642761fb72e25bbcfb11f90be2) — org/openlca/core/results/providers/ResultProvider.java, lines 585–597

    Caveats: This explains an existing diagnostic quantity and does not execute a new environmental impact method or real product evaluation.

    Premises referenced (1)
  67. Calculation. The same numeric zero can arise from different records; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (2)
  68. Calculation. The same numeric zero can arise from different records; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (1)
  69. Calculation. The same numeric zero can arise from different records; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (2)
  70. Analytical proposal. Reporting recommendation for characterization-coverage information states; not a verbatim requirement of the cited manual or ISO

    Caveats: This status classification is a reporting recommendation rather than a verbatim requirement of the cited manual or ISO standards.

    Premises referenced (2)
  71. Synthesis. Evidence layering across ILCD Format 1.1, native software controls, and impact-method records

    Caveats: The reporting statuses are a synthesis recommendation of this monograph and do not claim that all software tools implement these fields. The characterization status of an open technical flow cannot be inferred from whole-system totals alone; matching or item-level contribution evidence for that row is still required.

    Premises referenced (5)
  72. Analytical proposal. The same numeric zero can arise from different records; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (2)
  73. Synthesis. Reconnecting calculation mechanics to the evaluated service; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (3)
  74. Synthesis. Reconnecting calculation mechanics to the evaluated service; named cases using pinned source files and openLCA 2.7.0 native modules

    Premises referenced (1)
  75. Synthesis. Synthesis of bounded source comparisons, algebraic conditions, and named native-module observations

    Caveats: This does not prove universal equivalence across frameworks, universal correctness of any guide, or empirical validity of any real-world model.

    Premises referenced (6)

On this page