Contents · Full Text & Print
Appendix A Container Energy Verification
Audit glass-container manufacturing energy, upstream raw-material supply, and system-level totals from the 1974 EPA beverage-container study, and bound the discrepancy attributable to displayed-coefficient rounding.
This appendix extends the calculations in Beverage Container Studies. All cited tables come from the 1974 US Environmental Protection Agency (EPA) nine-beverage-container study introduced in that chapter. The sections below verify glass-container manufacturing energy, the combined glass-manufacturing and raw-material supply branch, and the maximum total-energy discrepancy that displayed-coefficient rounding can explain under fixed assumptions.
A.1 Process Inputs
Begin with the glass-container manufacturing stage, where the denominator is 1 short ton of finished glass containers. Volume II, Table 22 of the 1974 study lists five energy inputs per short ton of glass containers: 1.2 gallons of distillate oil, 5.5 gallons of residual oil, 10,700 cubic feet of natural gas, 0.023 gallons of gasoline, and 263 kilowatt-hours (kWh) of electricity. Interpreting any of these numbers requires stating both the energy carrier and the per-short-ton basis; applying the same figures directly on a "per bottle" or "per filling" basis alters their physical meaning.[1]
In the 1974 report, the total energy factors in Volume II, Table 1 are expressed in million British thermal units (Btu) per 1,000 gallons for liquid fuels and million Btu per 1,000 cubic feet for natural gas, while the electricity factor in Table 4 is expressed in million Btu per 1,000 kWh. Because the process inputs are tabulated in single gallons, cubic feet, or kWh, each input must first be divided by 1,000 to match the factor denominator. The five resulting contributions are 1.2 × 158.9 / 1,000, 5.5 × 169.9 / 1,000, 10,700 × 1.086 / 1,000, 0.023 × 144.9 / 1,000, and 263 × 11.1 / 1,000—all in million Btu per short ton of glass. Summing these five terms gives 15.6679627 million Btu per short ton, which rounds to 15.668 at three decimal places and matches the total glass-manufacturing energy of 15.668 reported in Table 14.[2]
A.2 Glass Manufacturing and Raw-Material Supply
With glass-container manufacturing energy verified, Volume II, Table 8 can be used to account for glass manufacturing together with its upstream raw-material supply. Table 8 is normalized to 1 short ton of the one-way glass (OWG) container system, meaning every entry is already scaled to the material quantity required for that system rather than to 1 short ton of each individual upstream process. On this shared per-short-ton system basis, the eight stages—feldspar mining (0.100), glass sand mining (0.569), natural soda ash mining (0.040), soda ash manufacturing (1.851), lime manufacturing (0.215), limestone mining (0.031), salt mining (0.049), and glass-container manufacturing (15.668)—sum to 18.523 million Btu. Because this subtotal already includes glass-container manufacturing, the 15.668 term must not be added a second time.[3]
Applying the same 18.523 million Btu per short ton branch coefficient to the new-glass mass (in short tons) required for each scenario yields 30.5 × 18.523 = 564.9515 million Btu for the 10-trip returnable glass scenario and 205 × 18.523 = 3,797.215 million Btu for the one-way glass scenario, both referenced to the same 1 million fillings. Because the two container systems differ in both bottle weight and trippage, this comparison does not isolate the effect of trippage alone. Moreover, the recalculation covers only glass manufacturing and upstream raw-material supply, not the full set of activities in either container system.[4]
A third scenario provides an additional cross-check on this scaling rule. At 5 trips per bottle, new glass demand is 61 short tons; multiplying 61 × 18.523 gives 1,129.903 million Btu, which rounds to 1,130 and matches the "Bottle system" column total of 1,130 in Volume II, Table 9. This agreement verifies only the glass-manufacturing and raw-material supply branch; it does not validate the remaining columns of Table 9 or the entire 5-trip container system.[5]
A.3 Error Bound for Displayed Rounding
The calculation below tests one specific explanation for the table-assembly discrepancy identified in the main chapter.
Assembling the full table falls 70.09 million Btu short of the total reported in the 1974 study. To test how much of that gap could stem from displayed-digit rounding alone, suppose only the 13 three-decimal-place coefficients drawn from Table 8 each carry a rounding error of at most 0.0005, while the 205 short tons of glass are held strictly fixed. Under those conditions, the maximum possible cumulative rounding error is 13 × 0.0005 × 205 = 1.3325 million Btu—far smaller than 70.09 million Btu. This bound rules out the hypothesis that displayed rounding of the listed coefficients alone explains the gap under fixed tonnage, but it does not account for undisclosed precision in bottle weight and is not an empirical uncertainty interval.[6]
Notes
Interpretation. Energy-input rows of Volume II, Table 22 of the 1974 EPA container study on the reported per-short-ton basis.
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume II, Table 22, p. 79 (energy input rows and respective units)
Caveats: These five inputs do not constitute the complete glass-system inventory and do not imply identical energy demands across all glass plants.
Premises referenced (1)
Calculation. Selected verification of raw energy inputs multiplied by total energy factors (including upstream supply) in Volume II of the 1974 EPA container study.
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume II, Table 22, p. 79 (energy input rows and respective units)
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume II, Section I.A, p. 44, and Table 1, p. 45 (Energy row, Total column)
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume II, Section I.B, p. 49, and Table 4, p. 50
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume II, Table 14, pp. 65–66 (glass manufacturing and selected energy rows)
Caveats: Factor denominators are 1,000 gal, 1,000 ft³, and 1,000 kWh, respectively; calculated decimal places do not represent measurement precision, and matching total energy does not independently verify the separate process and transport columns.
Premises referenced (2)
Calculation. Displayed coefficients for the eight glass-manufacturing and upstream inorganic raw-material stages in Volume II, Table 8 of the 1974 EPA container study.
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume II, Table 8, p. 59 (Energy summary row, sub-item column headers, and measurement basis)
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume II, Table 14, pp. 65–66 (glass manufacturing and selected energy rows)
Caveats: Entries share the Table 8 common system basis rather than summing per-short-ton outputs of separate processes; this branch excludes full secondary packaging, closures, filling, disposal, and separately itemized system transport.
Premises referenced (1)
Calculation. Conditional calculation combining disclosed new-glass tonnages with the Table 8 glass-branch coefficient.
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume II, Table 8, p. 59 (Energy summary row, sub-item column headers, and measurement basis)
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume II, pp. 88–91 (Table 29, Figure 4, and bottle-weight/ton basis notes)
Caveats: The same scaling factor is not applied to filling, return packaging flows, or all transport stages.
Premises referenced (2)
Calculation. Numerical cross-check between the Volume II, Table 9 bottle-system column and the published Table 8 branch coefficient.
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume II, Table 9, p. 60 (Energy summary in the Bottle system 61 tons column)
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume II, Table 8, p. 59 (Energy summary row, sub-item column headers, and measurement basis)
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume II, pp. 88–91 (Table 29, Figure 4, and bottle-weight/ton basis notes)
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume I, p. 29, first paragraph (with reference to scenario definitions on p. 28)
Caveats: Internal consistency within a single report does not constitute independent empirical replication.
Premises referenced (1)
Calculation. Author-constructed conditional upper bound on coefficient-rounding error, not a statistical analysis from the 1974 report.
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume II, Table 8, p. 59 (Energy summary row, sub-item column headers, and measurement basis)
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume II, pp. 88–91 (Table 29, Figure 4, and bottle-weight/ton basis notes)
- Resource and Environmental Profile Analysis of Nine Beverage Container Alternatives: Final Report (SW-91c / EPA530SW91C (1974); Volume I: Hunt/Franklin; Volume II: Hunt/Welch/Cross/Woodall) — Volume II, Table 7, p. 57, and Table 13, p. 64 (10-RET/OWG energy inputs and summary rows)
Caveats: No probability distribution is assumed and the full cause of the discrepancy is not inferred; holding 205 short tons fixed is a prerequisite of this bound.
Premises referenced (1)
Topic 2 Reading System Models
Using ecoinvent's system models to clarify which processes supply one another and who bears the environmental burdens of waste treatment and secondary material production.
Appendix B Guide Calculation Audit
Audit the original tables and balance equations of the CML 1992 Guide aluminum-foil toy model, distinguish local from finite parameter responses, and examine what information is retained when characterization factors are mapped into screening bins.